![FAR RAC 185 Instructions For Use Manual Download Page 12](http://html1.mh-extra.com/html/far/rac-185/rac-185_instructions-for-use-manual_3455643012.webp)
GB
12
Date 03-2016
Revisione - 02
RAC 185
RAC 185
0
I
I
L
F
E
B
C
D
A
H
G
RAC 185
Ø 130
Ø 22
285
60
315
57
0
I
RAC 185
0
I
TECHNICAL DATA
• Working pressure ..................................................
6,5 BAR
• Min. int. diam. of the compressed
air feeding hose ...................................
min. diam = 6 mm
• Air consumption per cycle .........................................
1,6 Nl
•
Maximum force
.........................................
6,5 BAR - 7500 N
• Weight ..................................................................
2,050 Kg
• Working temperature .............................................
-5°/+50°
• Root mean square in total acceleration frequency (Ac)
to which the arms are subjected. ..........................
1,9 m/s2
•
A-weighted emission sound pressure level
..............
68.6 dBA
•
Peak C-weighted instantaneous sound pressure
......
<130 dBC
•
A-weighted sound power
.........................................
89.4 dBA
AIR FEED
The air feed must be free from foreign bodies and humidity
in order to protect the tool from premature wear and tear of
the components in movement, therefore we suggest to use a
lubricating unit for compressed air.
MAIN COMPONENTS
A)
................................................................................. Nozzle
B)
.........................................................Sleeve carrying nozzle
C)
............................................................Balancer connection
D)
.................................................................... Nails container
E)
...........................................Nail container adjustment hook
F)
........................................................... O / I suction control
G)
...........................................................Traction push-button
H)
.......................................................................Starting lever
I)
................................................. Compressed air connection
L)
............................................................... Protection bottom
HOW TO USE YOUR RIVETING TOOL
(fig.
f1-f2
)
The
RAC185
riveting tool features a system that prevents it from
working when not correctly held by the operator.
To operate it, you must press the activation lever (
H
) with
your hand.
THIS SYSTEM ELIMINATES POINTLESS AIR CONSUMPTION.
Operation with suction of sheared nail
(fig.
f1
)
make sure that the control (
F
) is in position
I
; this will enable
the system for holding the rivet in the tool and recovering the
sheared nail.
Operation without suction of sheared nail
(fig.
f2
)
make sure that the control (
F
) is in position
O
; in this case the
sheared nail will fall out by gravity.
DO NOT PERFORM RIVETING OPERATIONS HOLDING THE
RIVET WITH YOUR FINGERS!
f1
f2