TROUBLESHOOTING
A)
COMMON PROBLEMS
No power supply on “beep” sound
o
Check power switch is on
o
Check power supply cable is properly inserted at plug and the conductors within the plug and
appliance are firmly connected
There is a “beep” sound at power on but the heat cannot be turned up
o
Place switch in the off position before turning the appliance on
Moving the switch between power settings does not change the number on the display
o
The switch is damaged, replace it
During normal operation the appliance stops responding; it automatically shuts down or the power
suddenly drops and then returns to normal
o
If no pan is detected, the appliance will automatically switch off. Turn the power off and on
again, normal operation will resume
o
The appliance has partially overheated. Check the grease filters are clean, and the air inlets and
outlets are not obstructed. Check the cooling fans are operating
The display shows “H”
o
The pan has become too hot. It is possibly dry. Add more food/liquid into the pot.
B)
ERROR CODES
I)
FLOOR STANDING INDUCTIONAPPLIANCEWITH SLIDING OR ROTATING CONTROLS
Flashing
code
Cause
Resolution
Blank
the input
transformer is
open or
damaged.
No power
detected.
1. Whether the input transformer of the processing method is connected
with the main board, The terminal plug is not plugged in.
2. Replace the input transformer and then detect again.
1 or E1
No compatible
cookware
detected
Place induction suitable pan on the associated heat zone
2 or E2
coil sensor over
heat
1. Check whether the coil cooling fan is working properly.
2. Wire disc sensor position is not installed correctly, causing interference
to the thermostat! (Replace the installation position).
3.
at ambient temperature, the thermistor resistance is around 68K (use
a multimeter to hit the resistance file 200K position,
measurement Whether the resistance of the thermistor is normal (the
thermistor resistance is 100K minus the ambient temperature = actual
resistance)