ramp is displayed for confirmation. Press: ACCEPT to save ramp or CANCEL to
exit without saving.
Hesitation Squeeze
7.2
On units equipped with the hesitation squeeze option it may be accessed using the
button labeled Hesitation Squeeze. Pressing this button will bring up the following
screen.
This allows a very random schedule to be programmed using user selected timing
intervals.
Select Motor Speed = Bc, select the empty box under Run Time and enter the
hesitation start time in minutes using the touch pad a right. The Start Time is the
elapsed time from the beginning of the test to the first hesitation squeeze start.
Select Next Ramp to enter first stop. The screen will re-initialize and you can select
STOP for motor speed and enter desired amount of time for STOP segment in Run
Time box. Selecting Next Ramp again will allow you to enter run time after first
STOP segment. If you wish to repeat the schedule for the remainder of the test
simply select AUTO REPEAT after 3 segments have been entered (Bc-STOP-Bc).
An infinite number of sequences can be input.