PURPOSE
The
timing
relay
PCS-517 is used to temporarily control
of
systems in
industrial and home automation. With the powerful features of work,
one-and
two-time
contained in the memory of the processor, allows
for the elimination of complex and costly control systems based on a
compilation of many channels in normal time. Unlike
potentiometers
relays allow very precise setting time
of enclose
, for example, 3h .-
47min - 19se
c
.
BUTTON FUNCTIONS
PROG
:
- pass to
PROGRAMMING
mode (hold >3sec).
- out from
PROGRAMMING
mode
OK
:
- entering of settings and pass to next position of settings
- preview of chosen function during of realization it
+
:
- change statue of setting by +1 in chosen PROGRAMMING position
(holding a button cause continuous change by +1 in loop)
-
:
-change statue of setting by - 1 in chosen PROGRAMMING position
(holding a button cause continuous change by - 1 in loop)
RESTART
:
-"reset" of processor -
necessary in the event of suspension of
work functions of the relay. Do not delete the
settings of
function and
tim
es
+
and
-
("hard" reset):
-delete (reset) of all times of all work finctions from memory (press
>3sec two button together). Timer automaticly set P00 function
(
Inactivity statue
)
DESCRIPTION OF DISPLAY AND CONTROL PANEL
time/work function
report of control
signal statue
START
RESET
PROG
OK
+
-
report of
PROGRAMMING function
reprt of time t1
reprt of time t2
reprt of joint
statue
FUNCTIONING
The relay implement one of the
set work
functions
accordance
with
to desired times. Positions of
joint
indicator shows
joint
status: ON -
enclosed
(
position
1-5); OFF - disconnected (
position
1-6). The display shows the currently measured time t1 (
ş
1
indicator on the display) or the time t2 (
ş
2 indicator on the
display) from the upper to zero.
Functions 1
÷
5
are activated by power supply.
After completion of
the function,
on
the display appears
inscription
END (end).
Next realization of
function
will start when you turn off and re-
connecting voltage or "reboot" the CPU. For the
se
functions
indicator
of status signal START display
ON
symbol.
Functions 6
÷
17
are activated by control signal START. After enclosed
power supplay, the relay is ready to implementation of work function.
O
n
the display appears
inscription
ON
.
After
giving
of the START signal relay launching function. After the
completion of returns to standby mode (waiting for another signal to
START).
For
these functions
giving
of the START signal is indicated on
rate
by
the symbol signal ON.
No
signal is indicated by the symbol OFF.
Function 18
- is activated by control signalSTART. After enclosed the
power supply relay is in stanby mode to implementation of work
function. On
the display appears
inscription ON
.
After gave START
signal relay will start implementation of function. On
the display
appears
inscription
END (end).
The relay does not respond to
subsequent signals START.
Next implementation of function
will start
when you turn off and re-connecting voltage or "reboot" the CPU. For
this f
unction
giving
a signal START is
indicated by ON symbol
on the
rate of control
signal. No signal is indicated by the symbol OFF.
-
To turn off the power during the performance of the
work
functions
cause
to stop the relay.
Joint
will remain in a position to disconnect
(po
s
.1-6). Re-
enclose
the power will start
function
from the
beginning.
-
Pressing the RESTART
button
during the implementation of the work
function
cause start
the
functions from the beginning.
ATTENTION!
DESCRIPTION OF WORK FUNCTIONS
i
nactivity statue
Un
t
5 9 0 8 3 1 2 5 9 1 6 2 7
F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
tel/fax +48 42 2152383; 2270971 POLAND
http:/www.fif.com.pl e-mail: [email protected]
TIMING RELAY
18 functions
Do not dispose of this device in the trash along with other waste!
According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
PCS-517.2
WARRANTY.
The F&F products are
covered by the 24 months warranty from
date of purchase. Effective only with
proof of purchase. Contact your dealer or
directly from us. For more information on
the procedures for filing complaints on
www.fif.com.pl/reklamacje
After give the power supply the joint stay in 1-6 position and start count
of set of lagged time.
After
counted
time t, the
joint is reconnect
in the
position 1-5 (
enclose
). The
next implementation of work mode is
possible after
disconnected a the
power
supply and its re-
enclosed
.