background image

PURPOSE

The 

timing 

relay 

 

PCS-517 is used to temporarily control 

of 

systems in 

industrial and home automation. With the powerful features of work, 
one-and 

two-time

 contained in the memory of the processor, allows 

for the elimination of complex and costly control systems based on a 
compilation of many channels in normal time. Unlike 

potentiometers

 

relays  allow very  precise  setting  time 

of  enclose

,  for  example,  3h  .- 

47min - 19se

c

.

BUTTON FUNCTIONS

PROG

:

- pass to  

PROGRAMMING

  mode (hold >3sec).

- out from  

PROGRAMMING 

mode

 

OK

:

- entering of settings and pass to next position of settings
- preview of chosen function during of realization it

:

- change statue of setting by +1 in chosen PROGRAMMING position   
(holding a button cause continuous change by +1 in loop)

:

-change statue of setting by - 1 in chosen PROGRAMMING position   
(holding a button cause continuous change by - 1 in loop)

RESTART

:

-"reset" of processor - 

necessary  in  the  event  of  suspension  of 

work functions of the relay. Do not delete the

 settings of

 function and 

tim

es

+

 and 

 -

 ("hard" reset):

-delete (reset) of all times of all work finctions from memory (press 
>3sec  two  button  together).  Timer  automaticly  set    P00    function 
(

Inactivity statue

DESCRIPTION OF DISPLAY AND CONTROL PANEL

time/work function

report of control
 signal statue
START

RESET

PROG

OK

+

-

report of
PROGRAMMING function 

reprt of time t1

reprt of time t2

reprt of joint 

statue

FUNCTIONING

The relay   implement one of the 

set work 

functions 

accordance 

with 

 to   desired times. Positions of 

joint

 indicator shows 

joint

 

status: ON - 

enclosed

 (

position

 1-5); OFF - disconnected (

position

 

1-6).  The  display  shows  the  currently  measured  time  t1  (

ş

indicator  on  the  display)  or  the  time  t2  (

ş

2  indicator  on  the 

display) from the upper to zero.

 

Functions 1

÷

are activated by power supply. 

After completion of 

the function, 

on 

the display appears

 inscription 

 END (end).

 

Next  realization  of

 

function 

will  start  when  you  turn  off  and  re-

connecting voltage or "reboot" the CPU. For the

se

 functions 

indicator 

of  status signal START display

 ON 

symbol.

Functions 6

÷

17

 are activated by control signal START. After enclosed 

power supplay, the relay is ready to implementation of work function.

 

O

the display appears

 inscription 

 

ON

.

 

After 

giving

  of  the  START  signal  relay  launching  function.  After  the 

completion of returns to standby mode (waiting for another signal to 
START). 

For

 these functions 

giving 

of the START signal is indicated on 

rate

 by 

the symbol  signal ON. 

No

 signal is indicated by the symbol OFF.

 

Function 18 

- is activated by control signalSTART. After enclosed the 

power  supply  relay  is  in  stanby  mode  to  implementation  of  work 
function.  On 

the  display  appears

  inscription  ON

.

    After  gave  START 

signal  relay  will  start  implementation  of  function.  On 

the  display 

appears

  inscription 

  END  (end).

 

The  relay  does  not  respond  to 

subsequent signals START. 

Next implementation of function

 will start 

when you turn off and re-connecting voltage or "reboot" the CPU. For 
this f

unction

 

giving

 a signal START   is 

indicated by ON symbol

 on the 

rate of control

 signal. No signal is indicated by the symbol OFF.

 

To turn off the power during the performance of the

 work

 functions 

cause

 to stop the relay. 

Joint

 will remain in a position to disconnect 

(po

s

.1-6).  Re-

enclose

  the  power    will  start 

function 

from  the 

beginning. 

-

 Pressing the RESTART

 button

  during the implementation of the work

 

function

 

cause start

 

the

 functions from the beginning.

ATTENTION!

DESCRIPTION OF WORK FUNCTIONS

i

nactivity statue

Un

t

5 9 0 8 3 1 2 5 9 1 6 2 7

F&F Filipowski sp. j.

Konstantynowska 79/81   95-200 Pabianice   

tel/fax +48 42 2152383; 2270971    POLAND

http:/www.fif.com.pl   e-mail: [email protected]

TIMING RELAY

18 functions

Do not dispose of this device in the trash along with other waste! 

According 

to the Law on Waste, electro coming from households free of charge and can 
give any amount to up to that end point of collection, as well as to store the 
occasion of the purchase of new equipment (in accordance with the principle 
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned 
in nature, pose a threat to the environment and human health.

PCS-517.2

WARRANTY.

  The  F&F  products  are 

covered by the 24 months warranty from 
date  of  purchase.    Effective  only  with 
proof of purchase. Contact your dealer or 
directly from us. For more information on 
the  procedures  for  filing  complaints  on   
www.fif.com.pl/reklamacje

After give the power supply the joint stay in 1-6 position and start count 
of set of lagged time.

 After 

counted 

 time t, the 

joint is reconnect 

in the 

position  1-5  (

enclose

).  The 

next  implementation  of  work  mode  is 

possible after 

 disconnected a the 

power

 supply and its re-

enclosed

.

 

Reviews: