lapse of 30 sec. programming mode is automatically deactivated.
Important! The telephone number of Alarm Receiver 1
must
be programmed to make an alarm.
Alarm Code 1 is default ‘1’ but
must
be programmed if the alarm is sent to an alarm central.
Activation of programming mode
6.2.1 First time used if unit is powerless
Remove the 8-pol connector and fasten the alarm button cords and telephone line cords. Press
down
and fasten the screw connector. The ECII™ Flex will automatically go into program-
ming mode. Once programming mode is entered this is confirmed by a tone in the loudspeaker.
This can also be used if the ECII™ Flex in operation; remove the connector and wait 10 seconds
for the unit to lose all power. Press down
and fasten the screw connector again.
6.2.2 Reprogramming ECII™ Flex
Press
and the alarm button simultaneously. Press for the same time as the selected time
for the alarm button, the default setting is 5 seconds. Once programming mode is entered this
is confirmed by a tone in the loudspeaker.
6.2.3 Call out from the ECII™ Flex
Once entered programming mode there is an option to call out a normal phone call from the
ECII™ Flex using the key pad. When the dial tone is heard; enter the phone number to call out
to a phone or press
to start programming the unit.
6.2.4 Reprogramming from phone
Call the telephone number to which the ECII™ Flex is connected and wait for the device to
answer. The ECII™ Flex will first answer with a modem tone and then switch to a 3-tone mes-
sage; please view section
Calls to a lift phone
for more information. Press #<ID>, default is 1.
Wait for the 3-tone message, then program the PIN CODE. Default code is 1111.
From phone:
# < PIN CODE> #
6.2.5 Indication and exit
The yellow and green LEDs will flash alternately when the ECII™ Flex is in programming mode.
Programming mode is deactivated automatically after 30 seconds if no key is pressed. Note
that some exchanges (mainly ISDN) sometimes disconnect the lift phone after a shorter time.
All programming must then be done at a different location. Normal alarms are not affected by
this.
You can also leave programming mode manually by pressing:
From keypad:
From phone:
000 #
Reset to factory settings
This function will reset the ECII™ Flex to its default settings; clearing all programmed receivers,
codes and settings; all but Alarm Code 1 which is default set to ‘1’.
Note: Reset to default setting will not erase speech messages. See section about speech
messages for information on how to erase speech messages.
From keypad:
From phone:
990 #
162187 Manual FältCom ECII™ Flex
Page 15 of 40