background image

Horizontal Lifeline –

 A component of a horizontal lifeline subsystem, consisting of a flexible line with connectors or other coupling means at both 

ends for securing it horizontally between two anchorages or anchorage connectors.

Horizontal Lifeline Subsystem –

 An assembly, including the necessary connectors, comprised of a horizontal lifeline component and, optionally, of: 

a) An energy absorbing component or, b) A lifeline tensioner component, or both. This subsystem is normally attached at each end to an anchorage 

or anchorage connector.  The end anchorages have the same elevation.

Lanyard -

 A component consisting of a flexible rope, wire rope or strap, which typically has a connector at each end for connecting to the body 

support and to a fall arrester, energy absorber, anchorage connector or anchorage.

Lanyard Connecting Subsystem - 

An assembly, including the necessary connectors, comprised of a lanyard only, or a lanyard and energy absorber.

Personal Fall Arrest System (PFAS) -

 An assembly of components and subsystems used to arrest a person in a free fall.

Positioning - 

The act of supporting the body with a positioning system for the purpose of working with hands free.

Positioning Lanyard - 

A lanyard used to transfer forces from a body support to an anchorage or anchorage connector in a positioning system.

Qualified Person -

 A person with a recognized degree or professional certificate and with extensive knowledge, training and experience in the fall 

protection and rescue field who is capable of designing, analyzing, evaluating and specifying fall protection and rescue systems.

Self-Retracting Device (SRD) - 

A device that contains a drum wound line that automatically locks at the onset of a fall to arrest the user, but that 

pays out from and automatically retracts onto the drum during normal movement of the person to whom the line is attached.

After onset of a fall, the device automatically locks the drum and arrests the fall. Self-retracting devices include self-retracting lanyards (SrL’s), 

self-retracting lanyards with integral rescue capability (SrL-r’s), and self-retracting lanyards with leading edge capability (SrL-Le’s) and, hybrid combi-

nations of these.

Snaphook - 

A connector comprised of a hook-shaped body with a normally closed gate or similar arrangement that may be opened to permit the 

hook to receive an object and, when released, automatically closes to retain the object. 

Swing Fall - 

A pendulum-like motion that occurs during and/or after a vertical fall. A swing fall results when an authorized person begins a fall from a 

position that is located horizontally away from a fixed anchorage.

MHLL12 Rev A

092117

16

Summary of Contents for HLL

Page 1: ...yee training program as required by the Occupational Safety and Health Administration OSHA The FallTech SteelGrip Temporary Cable Horizontal Lifeline HLL is designed as a temporary reusable anchorage...

Page 2: ...Labels 8 0 Definitions Appendix A 3 4 8 9 13 13 14 15 17 For the purposes of this manual the FallTech SteelGrip Temporary Horizontal Lifeline may be referred to as the HLL the system or the lifeline...

Page 3: ...sers experience more risk of serious injury or death due to falls because of increased fall arrest forces placed on the user s body In addition the onset of suspension trauma after a fall even may be...

Page 4: ...lGrip Temporary Cable HLL is a dynamic anchorage subsystem that will vary in its performance depending upon the length of the system the number of workers attached and the type of PFAS being used Care...

Page 5: ...irements prior to installation and use of the system See tables and charts below for calculating minimum required fall clearance 7 Freefall Distance scenario is only allowed when the SteelGrip Tempora...

Page 6: ...6 5 27 5 28 5 29 5 30 5 31 5 81 90 26 0 27 0 28 0 29 0 30 0 31 0 32 0 33 0 91 100 27 5 28 5 29 5 30 5 31 5 32 5 33 5 34 5 1 2 3 B C A Figure 4 SteelGrip Temporary Cable HLL with SAL Minimum Fall Clear...

Page 7: ...Level or Obstruction If SRD Deceleration Distance is unknown use 2 feet for ANSI Z359 14 Class A SRDs or use 4 1 2 feet for ANSI Z359 14 Class B SRDs Work below HLL to avoid Swing Fall Figure 5 Steel...

Page 8: ...Z359 14 allows up to 24 of deceleration for Class A SRDs and up to 54 of deceleration for Class B SRDs The charts below demonstrate clearance requirements below the working surface when using the Fall...

Page 9: ...hor Point of a Personal Fall Arrest System 4 5 Product Assembly and Installation System installation requires end anchor points that are a minimum of 5000 Lbs in both vertical and horizontal direction...

Page 10: ...kle with the open shackle on the FallTech Tension Indicator Insert a turnbuckle bolt through the aligned holes thread on the nut and insert the cotter pin as shown in Figure 11 Step 6 Align the other...

Page 11: ...the instructions in the FallTech SteelGrip Stanchion User Manual Ensure that the lifeline passes through the intermediate stanchion s pass through brackets as shown in Figure 21 Step 4 Holding the cab...

Page 12: ...3 Secure the HLL system to the anchorage connectors with the provided end attachment carabiners Step 4 Holding the cable side jaw of the turnbuckle to prevent the lifeline from twisting use a tool to...

Page 13: ...se Inspection Prior to each the HLL system should be inspected by the user for damage wear and to ensure the lifeline is properly tensioned Please review the inspection checklist for inspection requir...

Page 14: ...Model Modelo N ____________________ Date of Manufacture Fecha de fabricaci n ____________________ Serial N de serie ____________________ Inspection Date Fecha de inspecci n Inspector Inspector Comment...

Page 15: ...fall protection program who through training and knowledge is capable of identifying evaluating and addressing existing and potential fall hazards and who has the employer s authority to take prompt c...

Page 16: ...forces from a body support to an anchorage or anchorage connector in a positioning system Qualified Person A person with a recognized degree or professional certificate and with extensive knowledge t...

Page 17: ...nsion Indicator Zinc Plated Alloy Steel Maximum Two Workers at up to 310 lbs Each OSHA 1926 502 Specifications for FallTech SteelGrip Temporary Cable HLL Part SteelGrip Coil Energy Absorber Ferruled C...

Page 18: ...chor Water filled Counterweight 7435 Bolt on D Ring Anchor w integral stud 7435H Bolt on D Ring Anchor 7438 6 Cable Pass Through Sling Anchor 7440 Removeable Concrete Anchor 5K 7440S Removeable Concre...

Reviews: