F-40 Laminator Operator Manual
Installation
© GBC Pro-Tech 1998 February
2-7
WARNING
7.
Plug the laminator into an approved socket or have
a certified electrician wire the laminator directly to
a power source.
The laminator requires 30A single phase service
and a power receptacle that accepts a 30A 250V
NEMA L6-30P plug or, in Europe, 3 phase, 240/
400 VAC with 20A per phase. See Figure 2-6 for
power cord connection options.
8.
Verify that the photoelectric eye is working prop-
erly. (See the procedure below.)
9.
Replace both cabinet covers.
Figure 2-6: Power Cord Connection
ALWAYS CHECK THE INFRARED SENSORS
PRIOR TO OPERATION! The sensors must be
clean and have free view of the roll to maintain
proper roll operating temperatures. The rolls can
overheat and cause a fire or seriously damage
the laminator.