BOLERO-LT Hardware Description
Version 1.0.6
Average current consumption in sleep mode
Sleep Modes
approx. [mA]
IGN
0.42
IGN+Timer=0:5:00
*
11
*
GPS positions are reported every 5 minutes. Due to Timer timeout, device wakes up after 5 minutes, sends its position and
goes back to sleep.
Note:
These values may vary over time and environments condition can not be guaranteed.
Table 2.1:
Current consumption for different sleep modes
4.1.2 Operating temperatures
Parameter
Min.
Typ.
Max.
Unit
Storage temperature (
without internal battery)
-40
+25
+90
°C
Storage temperature (
with internal battery
)
-20
+25
+60
°C
Operating temperature (
without internal battery)
-40
+25
+85
°C
GSM
*
(
without internal battery
)
-30
+25
+80
°C
Charging temperature (
with internal battery
enabled **
)
0
+25
+45
°C
Discharging temperature (
with internal battery
enabled **
)
-20
+25
+60
°C
*
The extreme temperature can affect the sensitivity and performance of the GSM engine.
**
Using configuration
$PFAL,Cnf.Set,DEVICE.BAT.MODE=
auto
Table 2:
Operating temperature
This confidential document is a property of FALCOM and may not be copied or circulated without previous permission.
Page 17