BOLERO-LT Hardware Description
Version 1.0.6
6.1.3 Buttons & LEDs
BOLERO-LT comes with 1 x free-programmable push-button
(connected to the
DiWu-pin
known in the STEPPIII)
and 3 x free-programmable LED indicators that can be used to
indicate the status of different components in the the unit. The
"
On/Off
"
button
generates
(
IO.e9=redge
)
event when pressed, which can be used to power on the
unit. However, you have the possibility to configure this button depending on what
configuration is most important for you.
Figure 11:
On/Off button
All LED indicators are accessible with PFAL commands and they can be
interfaced to different components in the device to show their operation states.
The mode and functionality of these LEDs are software-controlled features.
References how to customize the device configuration, are available in the
BOLERO-LT
software
manual
“
steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf
”.
To set an LED indicator to high or low use the following PFAL commands:
$PFAL,IO
11[12,13]
.Set=high
[low; hpulse,1000; lpulse,1000; cyclic,1000,1000]
//sets LED1, LED2, or
LED3 to the specified level.
Figure 12:
Location of the LED indicators on the BOLERO-LT
BOLERO-LT is equipped with following LED indicators:
Indices on the firmware
LED status
IO11
Free programmable LED
IO12
Free programmable LED
IO13
Free programmable LED
Table 5
:
LED indicators available on the BOLERO-LT
This confidential document is a property of FALCOM and may not be copied or circulated without previous permission.