BOLERO-LT Hardware Description
Version 1.0.6
6.1.2.2 Digital Input (pin 6)
This pin is a high active when is used as digital input, so you can set
V
IN(LOW)
and
V
I
N(HIGH)
to any levels within the range from +0 to +32.0 VDC. The High and Low levels have to be
set by using the PFAL command (e.g.
PFAL,IO
0
.Config=DI,3,6
)
-
where 0 is the index
corresponding to IO1 (pin 6). While the value 3 and 6 are min. and max. voltages that
will be used to generate Low and High events respectively.
Detailed information can
be
found
in
software
manual
“
steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf
“
.
The figure below illustrates how to connect these pins and use them as digital inputs.
When an input is activated, BOLERO-LT can release an alarm (for instance a SMS, TCP
or GSM data connection). The alarm type and the alarm text are user dependent.
These
inputs
can
be
configured
by
using
the
“steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf”
manual. Both inputs
can be connected as shown below:
Figure 6:
Connection example for digital input (IO1)
A completed circuit example for all inputs is attached in section
8.1.1
.
This confidential document is a property of FALCOM and may not be copied or circulated without previous permission.