Page 52
-
Pull the BRSF pin to ground.
-
Start the flashburner.exe. Don’t change the MIPS Loader File
Path and the MIPS Executable File Path!
-
Select the serial port the modem is connected to and hit the
START DOWNLOAD button. If the power supply was
disconnected, reconnect it.
-
Pull the SOFT ON pin to HIGH until the LOADER PROGRAM
LOADING bar is filled (approx. 7 sec).
-
Release the SOFT ON. The program continues with ERASING
FLASH and BURNING FLASH.
-
Wait until update process is finished (this takes approx. 2 min 14
sec, then all bars are filled blue and the buttons are changing from
grey to black).
-
Hit EXIT.
-
Disconnect BRSF from ground.
-
Reset the module by using RSTF or disconnect the power supply.
The new software version is now implemented. It should be investigated by