7. As pic 11 shown, connect the 4 adjustable angle iron bracket with the housing by 

8pcs M4*12mm machine silk screw, next refer to pic 12/13, lift up the housing, use 

8pcs M4*12mm machine silk screw and M4 nut with gasket to fix the housing onto the 

2 hanging board, meanwhile, pull the expansion pipe outside.(Note: The expansion 

pipe must be fixed on the housing firmly.) 

8. After installing the housing to the hanging board, use cross screwdriver or straight 

screwdriver to adjust the screw of the angle iron bracket, direct the housing 

horizontally and to the required height. Adjust method: Adjust rang of the angle iron 

bracket is 0-25mm, clockwise swing the screw of the 4 angle iron bracket, slightly 

move the housing upwards; meanwhile, anticlockwise swing the screw of the angle 

iron bracket, slightly move the housing downwards. Use the cross screwdriver to 

screw the safety screw tightly after the level position and height is suitable.(Refer to 

pic 14)

 

 
 
 
 
 
 
 
 
 
 
 
HINTS FOR EXHAUST DUCT INSTALLATION 

The following rules must be strictly followed to obtain optimal air extraction: 

• Keep expansion pipe short and straight. 

• Do not reduce the size or restrict expansion pipe. 

• When using expansion pipe always install the pipe pulled taut to minimize pressure 

loss. 

• Failure to observe these basic instructions will reduce the performance and increase 

noise levels of the cooker hood. 

• Any installation work must be carried out by a qualified electrician or competent 

person. 

•Do not connect the ducting system of the hood to any existing ventilation system 

which is being used for any other appliance ,such as warmer tube, gas tube , hot wind 

tube. 

•The angle of the bend of the expansion pipe should not be less than 120º; you must 

direct the pipe horizontally, or, alternatively, the pipe should go up from the initial point 

and should be led to an outer wall. 

Summary of Contents for FAL-110-CEWG

Page 1: ...1 Cooker Hood Instruction Manual Model No FAL 110 CEWG...

Page 2: ...t is the correct installation height A The recommended installation height is 750mm above gas and 650mm above electrical On either application it is recommended that your installation height does not...

Page 3: ...ight bulbs Main Control Switches and motor fan blades are covered by our two year parts and labour guarantee 9 Q What is excluded from my warranty A Downlights and bulbs Glass panels and extractor gla...

Page 4: ...avoid being charged a This is a picture of the butterfly valve closed with the tape on top The tape should be removed when installed Both butterfly valves open when the extractor is switched on b Duc...

Page 5: ...5 Content 1 Safety instructions 2 Installation 3 Start using your cooker hood 4 Troubleshooting 5 Maintenance and cleaning 6 Environment protection...

Page 6: ...not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels Always to do Important Always switch off the electricity supply at the mains during installa...

Page 7: ...eful to avoid touching the heating elements Children younger than 8 years old should stay away unless they are under permanent supervision There shall be adequate ventilation of the room when the cook...

Page 8: ...a pin 3 should be top oriented the axis 4 should be inserted in the holes 5 on body repeat all the operations for the 2nd half part INSTALLATION If you have an outlet to the outside your cooker hood c...

Page 9: ...ce the installation height is determined see pic 2 14pcs anchor bolt or 14pcs of ST6 40mm big flat screws 14pcs wall plugs will be used to fix the two hanging board on the ceiling see pic 3 5 Calculat...

Page 10: ...that on the panel decorative strip c Unscrew the 8pcs machine silk from the bottom of the cabinet housing and rotate it by 90 180 270 to choose the direction of the outlet then screw the 8 pcs machin...

Page 11: ...g downwards Use the cross screwdriver to screw the safety screw tightly after the level position and height is suitable Refer to pic 14 HINTS FOR EXHAUST DUCT INSTALLATION The following rules must be...

Page 12: ...The light will shut off automatically after 30 seconds if without any operation On Off Switches the ventilation on and off Light Switches the light on and off Ventilation speed The motor has the low s...

Page 13: ...e used for speed selection lighting and timer setting If you want to connect again you will need to clear the code that has been set up previously To clear the code press for 5 seconds the indicators...

Page 14: ...service center Motor failed Contact service center Light does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to power outlet Switch pow...

Page 15: ...ife expectancy Dry with a clean soft cloth A specialized stainless steel cleaning fluid may be used NOTE Ensure that wiping is done along with the grain of the stainless steel to prevent any unsightly...

Page 16: ...minium filter should be detached first Firstly open carefully the stainless steel cover then press the lock of aluminium filter and remove it NOTE Make sure the filter is securely locked Otherwise it...

Page 17: ...at this product must not be disposed of with household waste but must be supported by a system of selective collection in accordance with Directive 2012 19 EU It will then be recycled or dismantled to...

Page 18: ...he appliance in a way which is not shown in the user manual The appliance could not be dismantled by user At the end of life the appliance should not be disposed of with household waste Check with you...

Page 19: ...warranty It is an express condition of these warranties that the purchaser takes due care and attention in the use and maintenance of the product appliance 3 Any physical damage to the product applia...

Reviews: