4.6.2 Excluding a device from the Z-Wave network using the ZWMP weather module (EXCLUDE
function)
Excluding a device from the “Z-Wave” network is possible only with the use of a PRIMARY
controller (e.g. keyboard ZWK15, ZWK1, ZWP15, ZWPTV). If the ZWMP module in the Z-Wave network is
marked as PRIMARY (network configuration as per section 4.6.1), then devices can be excluded only using
that module. The procedure of device excluding from the network with the use of the ZWMP module is
presented in
Figure 8.
*) Programming error results from the fact of not receiving any response from the device and may be caused
by:
•
failure to press the programming button within 10 seconds from the module signalling its readiness to
delete the device;
•
the device belonging to network other than module.
5 Technical parameters
Technical parameters
Power
230VAC
Working temperature
(+5
O
C) to (40
O
C)
Working range
to 40 [m]
Working frequency
868,43 MHz
Maximum cable length of the device plugged
into digital or analogue input
5 rm
11.09.21 NC815
11/16
©2011,
FAKRO
Figure 8: Excluding device from the Z-Wave network with the use of ZWMP weather module.
4
. The controller is signaling that the
device has been successfully excluded
form the network (two external LEDs
on for app. 2-3 sec.).
5*
. Programming error – two
middle LEDs flashing for app. 2-3
sec.
2
. The controller is signaling
readiness for excluding the device
from the network (two middle
LEDs on for 10 sec.).
3.
Press “P” button on the device and
hold it for 0.5 sec. (see Device
Programming Manual).
1
. Within 1 sec, press “
In/Ex
”
button twice.
O
C
Sel
In/Ex
4
3
2
1
O
C
Sel
In/Ex
4
3
2
1
x2
O
C
Sel
In/Ex
4
3
2
1
O
C
Sel
In/Ex
4
3
2
1
x1
Summary of Contents for ZWMP
Page 13: ...11 09 21 NC815 13 16 2011 FAKRO ...