background image

 1  Safety rules 

Read the instructions below carefully before proceeding to device installation so as to 
avoid electric shock, injury etc. 

CAUTION!!!

The   ZWMP   weather   module   is   powered   by   230V   alternating   current.   Electric   shock 
hazard.  

When   installing   the   ZWMP   module   it   is   crucial   to   pay   close   attention   to   the   following 
recommendations: 

Installation   should   be   performed   by   a   qualified   individual   following   manufacturer's 
instructions.

Connecting the module should be performed with power supply disconnected at all times.  

After unpacking, check module elements for any signs of mechanical damage.  

Before connecting the module, make sure that the power supply voltage corresponds with 
that provided on the data plate.  

Plastic containers used for packing should be kept out of children's reach as thy may be a 
potential source of hazard.  

The ZWMP module should be used for its intended purpose in agreement with its design. 
The FAKRO Company shall not be held responsible for any consequences resulting from 
improper module use.  

Any activities relating to cleaning, adjustment or disassembly of the module   should be 
preceded with its disconnection from the mains.  

The module should not be cleaned using any solvent substances or open stream of water 
(do not immerse in water). 

Any module repairs should be carried out by the manufacturer authorised service.  

Electric   cables   supplying   electricity   to   the   source   of   power   must   have   suitable   area 
(2x1mm

2

). The permissible cable length for the area specified above is 30 rm.  

The permissible length of cables plugged into digital inputs is 5rm.  

The ZWMP weather module is intended for indoor installation.  

11.09.21 NC815

2/16

©2011, 

FAKRO

Summary of Contents for ZWMP

Page 1: ... CLOSE buttons 7 4 3 Device deleting from ZWMP weather module DELETE function 8 4 4 Return to default settings of the ZWMP weather module DEFAULT function 9 4 5 Removing the ZWMP weather module from the network 9 4 6 Additional functions 10 4 6 1 Configuring the Z Wave network using the ZWMP weather module INCLUDE function 10 4 6 2 Excluding a device from the Z Wave network using the ZWMP weather ...

Page 2: ...ed for packing should be kept out of children s reach as thy may be a potential source of hazard The ZWMP module should be used for its intended purpose in agreement with its design The FAKRO Company shall not be held responsible for any consequences resulting from improper module use Any activities relating to cleaning adjustment or disassembly of the module should be preceded with its disconnect...

Page 3: ...h channel 2 are operated from digital input No 2 channel 3 are operated from digital input No 3 etc The devices associated with one of the channels can only OPEN or CLOSE after sending a signal to its digital input The ZWMP weather module is equipped with two way Z Wave communication system For communication the Z Wave system utilises radio wave frequency of 868 43 Mhz In Figure 1 there is present...

Page 4: ... upper section of the casing 2 Take out the screws fixing electronic plate to the casing see Figure 1 3 Take electronic plate out of the casing 4 Screw the lower section of the casing to the wall 5 Screw electronic plate to the lower section of the casing 6 Make all the necessary electric connections 7 Remount the upper section of the casing 11 09 21 NC815 4 16 2011 FAKRO Figure 2 ZWMP weather mod...

Page 5: ...ecifying the task to be performed by it chapter 4 2 ASSOCIATE function O open raise blind C close lower blind Caution Every device physically removed from the network e g in case of damaged needs to be deleted from the network Sec 4 6 2 so as to ensure the optimum communication between devices Disconnecting a device without deleting it from the controllers memory will result in prolonged reaction ...

Page 6: ...ontroller is signalling its readiness for adding a new device to the network long distance between the controller and ZWMP module the module is associated with another network and it is necessary to carry out the DEFAULT procedure first 11 09 21 NC815 6 16 2011 FAKRO Figure 3 Associating ZWMP module with Z Wave network 3 Module is signaling start of associating with the network two LEDs on as pres...

Page 7: ...pressed momentarily app 0 3sec runs the device until it reaches its extreme position i e motor chain or blind folded or unfolded completely In order to stop the device it is necessary to keep the button pressed for longer than 1 second CAUTION The ZWMP module does not provide a possibility to operate the device both ways e g blind lowering and raising from the same digital input channel 11 09 21 N...

Page 8: ...vice belonging to network other than module 11 09 21 NC815 8 16 2011 FAKRO Figure 5 Device deleting from ZWMP module channel 4 Press P button on the device and hold it for 0 5 sec see Device Programming Manual 2 Within 1 5 sec press In Ex button twice and C or O button depending on how the device has been associated 6 Programming error LEDs flashing for app 2 3 sec 1 Using SEL button choose a chan...

Page 9: ...n Figure 6 4 5 Removing the ZWMP weather module from the network Removing the ZWMP module from the network consists in restoring default settings in this module 11 09 21 NC815 9 16 2011 FAKRO Figure 6 Restoring default settings in ZWMP controller 1 Within 1 5 sec press In Ex button twice and then SEL button once 2 The controller is signallling that default settings have been restored alternate fla...

Page 10: ...ness for adding the device to the network long distance between the module and the device being added the module has been earlier associated with the network as SECONDARY it is necessary to perform DEFAULT procedure 11 09 21 NC815 10 16 2011 FAKRO Figure 7 Removing device from the Z Wave network using ZWMP weather module 4 The controller is signaling that the device has been successfully associate...

Page 11: ...evice the device belonging to network other than module 5 Technical parameters Technical parameters Power 230VAC Working temperature 5O C to 40O C Working range to 40 m Working frequency 868 43 MHz Maximum cable length of the device plugged into digital or analogue input 5 rm 11 09 21 NC815 11 16 2011 FAKRO Figure 8 Excluding device from the Z Wave network with the use of ZWMP weather module 4 The...

Page 12: ...wing conditions Installation has been performed by an authorised individual as per manufacturer recommendations Seals remain intact and no unauthorised structural changes have been made The device has been used in accordance with its intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena The manufacturer is not liable for damage which o...

Page 13: ...11 09 21 NC815 13 16 2011 FAKRO ...

Page 14: ...11 09 21 NC815 14 16 2011 FAKRO ...

Page 15: ...11 09 21 NC815 15 16 2011 FAKRO ...

Page 16: ...FAKRO PP Sp z o o ul Wegierska 144A 33 300 Nowy Sącz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 11 09 21 NC815 16 16 2011 FAKRO ...

Reviews: