3.14 System Configuration
FTP series power supply system parameters configuration ways:
1. Press
, select “System” sub menu under “Set”, press
to enter into system parameter set:
Figure 3-32 System Parameter Set
2. Rotate the rotary knob to select the parameter to be set, press
to enter into edit state;
3. Press number key and decimal point key to input value, or rotate the knob to increase/decrease value;
4. Press
to validate the input;
5. Power down the instrument, power on again for parameters to take effect.
----------------------------------------------------------------------------------------------------------------------
After modifying the configuration, you need to restart the power supply for changes to
take effect.
----------------------------------------------------------------------------------------------------------------------
3.14.1 Power Save
This parameter determines the initializing parameters when power supply is powered on, there are two choices:
●
On, use the parameter setting in last power-off;
●
Off, use the system default parameter
3.14.2 Power Output
This parameter determines whether power supply output is automatically turned on at the moment of power on,
there are two choices:
●
Off, when power supply is powered on, its output is turned off;
●
On, when power supply is powered on, its output is turned on.
-----------------------------------------------------------------------------------------------------------------------
To enable this configuration, must enable “Power Save” parameter first.
-----------------------------------------------------------------------------------------------------------------------