FTP Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 20 -
V-SENSE terminal explanation:
①
+LS: local V-sense positive terminal;
②
-LS: local V-sense negative terminal;
③
+S: remote V-sense positive terminal;
④
-S: remote V-sense negative terminal
----------------------------------------------------------------------------------------------------------------------
The allowed compensation voltage is relating to model voltage ratings, for specifics please refer to
“3.8.2 Over Compensate Voltage Protection (OCVP)”
----------------------------------------------------------------------------------------------------------------------
2.7.5 Analog Interface
FTP series power supply provides optional analog Interface at its rear panel. This interface has the functions of
analog programming input, voltage/current monitoring output, external control, power supply status and work
mode indication.
Figure 2-11 Analog Interface