- 41 -
V_Set
Output voltage for current step, Range 0 ~ max. Output voltage
I_Set
Output current for current step, Range 0 ~ max. Output current
Step-Time
Delay for current step, range 0.001 ~ 86400s. The delay time is counting from the moment
that the current step V/I reaches the setting value.
Program Sequence (SEQ):
1. Press
;
2.
Select “Sequence” sub menu under “Edit”, press “Enter” to enter into sequence file choosing page;
3.
Rotate the rotary knob or input numbers to choose a sequence file for editing, press “Enter” to enter SEQ editing
page shown as below:
Figure 3-29 Sequence File Edit
4. Set “Length”, press
to validate it, the editing cursor will move to “Cycle” automatically;
5. Set “Cycle”, press
to validate it, the editing cursor will move to “Link” automatically;
6. Set “Link”, press
to validate it, the editing cursor will move to “SEQ Step” automatically;
7. Set “SEQ Step”, press
to validate it, the editing cursor will move to “V_Set” automatically;
8. Set “V_Set”, press
to validate it, the editing cursor will move to “I_Set” automatically;
9. Set “I_Set”, press
to validate it, the editing cursor will move to “SEQ-Delay” automatically;
10. Set “SEQ-Delay”, press
to validate it, the editing cursor will move to “SEQ step” and increase its value by
1 automatically;
11. Repeat procedures of 7 ~ 10, till all sequence steps have been programmed.
12. Press
to save the programmed sequence file.
13. Press
to quit sequence editing.