Drive modules
188
3.
DRIVE MODULES
Co
mpact d
riv
es
148
DDS
HARDWARE
Ref.1310
Load duty cycles
Load cycle S1 with current peak
Load cycle S6
Load cycle S6 with current peak
Definition of currents
On axes:
In
“Continuous duty cycle” current.
Ip
Peak current.
See load duty cycles.
On spindles:
In
“Continuous duty cycle” current.
IS6-40%
Current that, in an intermittent duty cycle S6 with 10 min-
ute cycle, circulates for 4 minutes with load (the other 6 minutes oper-
ates without load); in other words with magnetizing current = 0.7 x
rated current In).
Imax
Maximum peak current.
See load duty cycles.
Note.
The values of these currents are given in RMS.
F. H3/85
Load cycle S1 with current peak.
F. H3/86
Load cycle S6-40.
F. H3/87
Load cycle S6 with current peak.
I
t
S1 cycle with
current peak
0.5 s
10 s
Ip
I
N
I
t
S6 cycle
4 min
10 min
0.7 x I
N
I
N
I
S6-40
I
MAX
I
t
S6 cycle with
current peak
10 s
60 s
0.7 x I
N
I
N
I
S6-40
I
MAX
Summary of Contents for APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1310...
Page 6: ...I 6 DDS HARDWARE Ref 1310...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...16 Ref 1310 DDS HARDWARE...
Page 30: ...1 DESCRIPTION 30 Description DDS HARDWARE Ref 1310...
Page 94: ...2 POWER SUPPLIES 94 Power supplies DDS HARDWARE Ref 1310...
Page 188: ...3 DRIVE MODULES 188 Drive modules DDS HARDWARE Ref 1310...
Page 204: ...4 AUXILIARY MODULES 204 Auxiliary modules DDS HARDWARE Ref 1310...
Page 232: ...SELECTING CRITERIA 5 232 Selection criteria DDS HARDWARE Ref 1310...
Page 266: ...7 CABLES 266 Cables DDS HARDWARE Ref 1310...
Page 312: ...8 INSTALLATION 312 Installation DDS HARDWARE Ref 1310...
Page 326: ...9 FUNCTIONAL SAFETY 326 Functional safety DDS HARDWARE Ref 1310...
Page 354: ...10 CONNECTION DIAGRAMS 354 Connection diagrams DDS HARDWARE Ref 1310...
Page 378: ...12 SALES REFERENCES 378 Sales references DDS HARDWARE Ref 1310...
Page 384: ...13 COMPATIBILITY 384 Compatibility DDS HARDWARE Ref 1310...
Page 385: ......