99
16/11/2012
74
HEATING
HEATING
HEATING
HEATING SYSTEM IN STEAM MODE (moist heat)
SYSTEM IN STEAM MODE (moist heat)
SYSTEM IN STEAM MODE (moist heat)
SYSTEM IN STEAM MODE (moist heat)
The STEAM heating mode uses resistors in the ELECTRIC MODEL and gas burners in the GAS MODEL.
First determine the capacities of the STEAM GENERATORS
STEAM GENERATORS
STEAM GENERATORS
STEAM GENERATORS by model:
The following modification should also be considered: NEW DESIGN of the STEAM GENERATOR
NEW DESIGN of the STEAM GENERATOR
NEW DESIGN of the STEAM GENERATOR
NEW DESIGN of the STEAM GENERATOR with the base inclined as
shown in the top photo. This change has helped to improve the cleaning of the BOILER.
The element common to the steam generator for both the electric and gas models is the LEVEL BOTTLE
LEVEL BOTTLE
LEVEL BOTTLE
LEVEL BOTTLE. This is the same in
both models, as described below:
HEATING SYSTEM STEAM GENERATOR ELECTRIC OVENS
HEATING SYSTEM STEAM GENERATOR ELECTRIC OVENS
HEATING SYSTEM STEAM GENERATOR ELECTRIC OVENS
HEATING SYSTEM STEAM GENERATOR ELECTRIC OVENS
AE-APE
AG-APG
061
3.25 litres
7.3 litres
101
5.5 litres
7.3 litres
201
7 litres
12.3 litres
102
7 litres
12.3 litres
202
11.7 litres
15.3 litres
Summary of Contents for ADVANCE CONCEPT
Page 20: ...16 11 2012 20 ACE 061 AE 061 APE 061 A Soft water intake C Mains supply D Drainage...
Page 21: ...16 11 2012 21 ACE 101 AE 101 APE 101 A Soft water intake C Mains supply D Drainage...
Page 22: ...16 11 2012 22 ACE 201 AE 201 APE 201 A Soft water intake C Mains supply D Drainage...
Page 23: ...16 11 2012 23 ACE 102 AE 102 APE 102 A Soft water intake C Mains supply D Drainage...
Page 24: ...16 11 2012 24 ACE 202 AE 202 APE 202 A Soft water intake C Mains supply D Drainage...
Page 86: ...99 16 11 2012 86...
Page 92: ...99 16 11 2012 92...
Page 93: ...99 16 11 2012 93...
Page 94: ...99 16 11 2012 94...
Page 95: ...99 16 11 2012 95...