WASTE WATER CONNECTION
Incorrect installation of the oven may result in the incorrect operation of the
appliance.
Therefore, the drainage Kit supplied by the manufacturer should be installed (Fig.
12). This drainage system should be connected to an open tank or grille.
Installation (Fig. 13 Fig. 14.) should be in such a way as to ensure that the installed
drainage outlet is below the oven outlet with a suitable slope to ensure drainage
(>5% or 3º).
Make sure that the holes on the rising pipe face the side opposite the rear panel to
prevent condensation.
Ensure the measurements for the drainage are correct:
- Steam generator pumping volume in a reduced space of time: 0.7 l/second.
- Average temperature of waste water: 65 ºC
.
Fig.13: Table top models 061-101-102
Fig. 14: Models 201 and 202