16/11/2012
28
1. Checking installation
1. Checking installation
1. Checking installation
1. Checking installation
YES
YES
YES
YES NO
NO
NO
NO
a) Is the floor level?
a) Is the floor level?
a) Is the floor level?
a) Is the floor level?
If “NO”, what is the difference in level?
If “NO”, what is the difference in level?
If “NO”, what is the difference in level?
If “NO”, what is the difference in level?
...........................................
...........................................
...........................................
...........................................
%
%
%
%
(max. 2%)
(max. 2%)
(max. 2%)
(max. 2%)
b) Is there any source of heat at less than 500 mm from the oven?
b) Is there any source of heat at less than 500 mm from the oven?
b) Is there any source of heat at less than 500 mm from the oven?
b) Is there any source of heat at less than 500 mm from the oven?
If “Yes”, the installation of heat protection is obligatory.
If “Yes”, the installation of heat protection is obligatory.
If “Yes”, the installation of heat protection is obligatory.
If “Yes”, the installation of heat protection is obligatory.
c) Is there any other equipment at less than 500 mm from the oven?
c) Is there any other equipment at less than 500 mm from the oven?
c) Is there any other equipment at less than 500 mm from the oven?
c) Is there any other equipment at less than 500 mm from the oven?
If “Yes”, what type of equipment?
If “Yes”, what type of equipment?
If “Yes”, what type of equipment?
If “Yes”, what type of equipment?
.....................................................................
.....................................................................
.....................................................................
.....................................................................
d) Has a hood/extractor system been installed?
d) Has a hood/extractor system been installed?
d) Has a hood/extractor system been installed?
d) Has a hood/extractor system been installed?
e)
e)
e)
e) For gas ovens without an extraction system, has the draught diverter been
For gas ovens without an extraction system, has the draught diverter been
For gas ovens without an extraction system, has the draught diverter been
For gas ovens without an extraction system, has the draught diverter been
installed?
installed?
installed?
installed?
If “YES”, is the pipe Ø equal to 280 mm?
If “YES”, is the pipe Ø equal to 280 mm?
If “YES”, is the pipe Ø equal to 280 mm?
If “YES”, is the pipe Ø equal to 280 mm?
f) Is there a FAGOR extractor hood installed?
f) Is there a FAGOR extractor hood installed?
f) Is there a FAGOR extractor hood installed?
f) Is there a FAGOR extractor hood installed?
If “Yes”, what model is it?
If “Yes”, what model is it?
If “Yes”, what model is it?
If “Yes”, what model is it?
……………………………………
……………………………………
……………………………………
……………………………………
What is the serial No?
What is the serial No?
What is the serial No?
What is the serial No?
……………………………….
……………………………….
……………………………….
……………………………….
g) For floor models (201, 202), is there enough space for the trolley?
g) For floor models (201, 202), is there enough space for the trolley?
g) For floor models (201, 202), is there enough space for the trolley?
g) For floor models (201, 202), is there enough space for the trolley?
h) Is the oven level?
h) Is the oven level?
h) Is the oven level?
h) Is the oven level?
i) For table top models (061, 101, 102), is the table level?
i) For table top models (061, 101, 102), is the table level?
i) For table top models (061, 101, 102), is the table level?
i) For table top models (061, 101, 102), is the table level?
j) For floor models, (201, 202), is the oven trolley level and adjusted?
j) For floor models, (201, 202), is the oven trolley level and adjusted?
j) For floor models, (201, 202), is the oven trolley level and adjusted?
j) For floor models, (201, 202), is the oven trolley level and adjusted?
2. Electrical Installation
2. Electrical Installation
2. Electrical Installation
2. Electrical Installation
a) What voltage is shown on the registration plate?
a) What voltage is shown on the registration plate?
a) What voltage is shown on the registration plate?
a) What voltage is shown on the registration plate?
………
………
………
………
AC /
AC /
AC /
AC /
…………..
…………..
…………..
…………..
V /
V /
V /
V /
…….
…….
…….
…….
Hz
Hz
Hz
Hz
b) What voltage is available at the installation?
b) What voltage is available at the installation?
b) What voltage is available at the installation?
b) What voltage is available at the installation?
.……...
.……...
.……...
.……...
AC /
AC /
AC /
AC /
……….….
……….….
……….….
……….….
V /
V /
V /
V /
…….
…….
…….
…….
Hz
Hz
Hz
Hz
c) Measured voltage at the installation:
c) Measured voltage at the installation:
c) Measured voltage at the installation:
c) Measured voltage at the installation:
Phase 1
Phase 1
Phase 1
Phase 1 –––– Phase 2 ____________V Phase 1
Phase 2 ____________V Phase 1
Phase 2 ____________V Phase 1
Phase 2 ____________V Phase 1 –––– Neutral ____________V
Neutral ____________V
Neutral ____________V
Neutral ____________V
Phase 1
Phase 1
Phase 1
Phase 1 –––– Phase 3 ____________V Phase 2
Phase 3 ____________V Phase 2
Phase 3 ____________V Phase 2
Phase 3 ____________V Phase 2 –––– Neutral ______
Neutral ______
Neutral ______
Neutral _______
_
_
______V
_____V
_____V
_____V
Phase 2
Phase 2
Phase 2
Phase 2 –––– Phase 3 ____________V
Phase 3 ____________V
Phase 3 ____________V
Phase 3 ____________V
Phase 3
Phase 3
Phase 3
Phase 3 –––– Neutral _____
Neutral _____
Neutral _____
Neutral ______
_
_
_______V
______V
______V
______V
Neutral
Neutral
Neutral
Neutral –––– Earth ____________V
Earth ____________V
Earth ____________V
Earth ____________V
d) Electrical consumption by phase:
d) Electrical consumption by phase:
d) Electrical consumption by phase:
d) Electrical consumption by phase:
Phase 1
Phase 1
Phase 1
Phase 1
……....
……....
……....
……....
A Phase 2
A Phase 2
A Phase 2
A Phase 2
……….
……….
……….
……….
A Phase 3
A Phase 3
A Phase 3
A Phase 3
……….
……….
……….
……….
A
A
A
A
YES
YES
YES
YES NO
NO
NO
NO
e) Are there any electrical
e) Are there any electrical
e) Are there any electrical
e) Are there any electrical protections in the installation?
protections in the installation?
protections in the installation?
protections in the installation?
If “Yes”, what types?
If “Yes”, what types?
If “Yes”, what types?
If “Yes”, what types?
Magneto
Magneto
Magneto
Magneto thermal
thermal
thermal
thermal
…….
…….
…….
…….
A Fuses
A Fuses
A Fuses
A Fuses
…….
…….
…….
…….
A
A
A
A D
D
D
Differential
ifferential
ifferential
ifferential
…….
…….
…….
…….
mA
mA
mA
mA
(300 mA)
(300 mA)
(300 mA)
(300 mA)
f) Can the electrical panel be accessed by the user?
f) Can the electrical panel be accessed by the user?
f) Can the electrical panel be accessed by the user?
f) Can the electrical panel be accessed by the user?
Summary of Contents for ADVANCE CONCEPT
Page 20: ...16 11 2012 20 ACE 061 AE 061 APE 061 A Soft water intake C Mains supply D Drainage...
Page 21: ...16 11 2012 21 ACE 101 AE 101 APE 101 A Soft water intake C Mains supply D Drainage...
Page 22: ...16 11 2012 22 ACE 201 AE 201 APE 201 A Soft water intake C Mains supply D Drainage...
Page 23: ...16 11 2012 23 ACE 102 AE 102 APE 102 A Soft water intake C Mains supply D Drainage...
Page 24: ...16 11 2012 24 ACE 202 AE 202 APE 202 A Soft water intake C Mains supply D Drainage...
Page 86: ...99 16 11 2012 86...
Page 92: ...99 16 11 2012 92...
Page 93: ...99 16 11 2012 93...
Page 94: ...99 16 11 2012 94...
Page 95: ...99 16 11 2012 95...