![FAG Detector III Manual Download Page 92](http://html1.mh-extra.com/html/fag/detector-iii/detector-iii_manual_3173195092.webp)
92
Fullscreen
Click on
Fullscreen
to view this graphic in the size of your monitor
Show additional bearing
Click
Show additional bearing
to select a bearing from the bearing database
and display its frequencies in a trend diagram.
Toolbar
Click
Toolbar
to show/hide Viewer toolbar. For further information, please refer to
the description of the FIS-Viewer in the "Toolbar
" section.
Time signal, FFT signal
When in a trend diagram a certain value is surrounded by a small circle, then there
is at least one time signal for this measurement. You can view this time signal by
marking the value with the cursor and then clicking on
Time signal/FFT
. When
there is no time signal for the selected value, then this symbol is grey and cannot
be selected.
Print time signal, print FFT signal
Click these buttons to include the respective signal in the trend report (cf.
"Printing").
Click
to create a trend report. The trend report combines the diagrams of the
selected measured data for printing. Each diagram is printed on a separate page.
More detailed information on the viewer can be found here
.
3.9 Reset Alarm Status
In the system structure for each element the Trendline software displays whether
an alarm or pre-alarm was measured (also see Main window
). It may be
sensible to reset this alarm status if the cause of an alarm has been identified and
eliminated. The alarm status must be reset manually by the user as this decision
cannot be made by the Trendline software.
·
To reset the alarm status for a configurations element (e.g. machine or motor)
and the associated sub-elements, click on the element in the system tree.
·
Then click
System
>
Alarm Status Reset
.
68
115
114
30