168
English
English
The sub-menu of the Version entry shows the memory display
version:
When the PROG (
32
) key is pressed displays the data for the revision
and memory date.
Version
INFO
VERSION
+
u
u
VERSION
DISPLAY 029.T0.A0
+
u
u
DISPLAY 029.T0.A0
REV. 00 20/04/2006
The “Setup” entry displays the setup settings introduced during the
Data Standard insertion phase:
Setup
– –
Æ
Æ
Æ
Æ
Æ
Capp. - coffee
Steam
TS
Electric
Menu 1
INFO
SETUP
+
u
u
Entering Standard Data
******************
NEW SOFTWARE VERSION
LOAD
STANDARD DATA
******************
Before performing this operation, switch off the machine and position
dipswitch 1
on display screen =
ON
, then switch on the machine.
If the procedure described above is not performed (dip1=ON), this
message will appear on the display:
Using the "+" key (
34
) and the "-" key (
35
), select the parameters,
then press the PROG (32) to confirm the details.
After this operation, switch off the machine and reset the
dipswitch
1
display screen to
OFF
.
Then:
- Switch on the machine again
- Reset date and time, and reset the desired language, if needed.
- Zero the error log.
When inputting the Standard Data, you are prompted to input data
regarding model and type of machine:
-
MODEL:
2, 3, 4 groups;
-
TYPE:
coffee, cappuccino;
-
STEAM:
YES / NO (steam button);
-
TURBOSTEAM:
YES / NO;
-
FEEDING:
electric, el gas, gas;
-
MENU:
different types of drinks
8.
Technician programming - Configuration menu - Data menu
STANDARD DATA
– –
Æ
Æ
Æ
Æ
Æ
4 GR