min 80 cm
!
!
Visual 344
ø 275
CHIS 37
Elpro S40
min. 1,0 m
min. 1,0 m
1.890
ARRANGING FOR THE MAGNETIC LOOPS (OPTIONAL)
IMPORTANT: Make sure that the area near and below the ground level
where the accessories are installed is clear from electromagnetic
sources to prevent interference problems with the detections of the
loops and with any other electronic device to control the installation.
The magnetic loop is a safety device, permanently active, to detect
vehicles: the bollard is prevented from rising while any vehicle is transiting
on the loops.
A hole is to be dug to take the pre-assembled loops that can be provided
by the company (see the instructions coming with this item to be informed
about all of the possible configurations available).
Pic. 9
Entry loop
Exit loop
Pic. 10
- Pre-assembled loop, 6 metres
circumference (optional, see catalogue).
- Pre-assembled loop, 12 metres
circumference (optional, see catalogue).
Power supply cable
max 10 metres,
pre-fitted to the loops
Detector for metallic masses.
See the instructions supplied
with it.
(Optional, see catalogue).
(See the instructions provided with this item)
magnetic loop
INSTALLING THE PHOTOCELLS (OPTIONAL ITEM) AND OTHER COMMAND ACCESSORIES AS REQUIRED
The photocells are to be installed at a suitable minimum distance to operate properly as indicated in Pic. 11.
Visual 344, with 2 or 3 elements, is a post made of metal designed to provide a support to the electronic controller Elpro S40 in
those applications in the open where no other structures are available to this purpose. it is designed to also take any other control
accessories, such a key-switch or a video-intercom system, as required near the installation (Pic. 11).
Photocell
FIT 55
Photocell
FIT 55
Pic. 11
Electric cables laid underground through a corrugated sheath
Photocell
FIT 55
Photocell
FIT 55
Retractable Oil-hydraulic Bollard
English
9