Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not
indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of
materials or accessories not approved by the company itself.
It is to be noted that the product respects the impact and breakout resistance values as indicated provided
that the installation of the same is carried out in observance of the specifications included in this manual of
instructions. Various factors are to be carefully taken into consideration such as compaction index, soil
permeability coefficient, concrete type, which may affect the indicated values even significantly.
This symbol indicates that a particular attention is required on the installation phases and on running the
operator. Failure to observe these indications may cause incorrect functioning of the bollard.
INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM
1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by qualified and authorized
technicians in compliance with the existing regulations (www.fadini.net/supporto/download)
2) This automatic system is intended to be exclusively used for the applications described in this manual, including all of the
safety and command accessories, at least as required.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system
5) Make sure the site is free from utilities that may interfere with it.
6) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop detectors.
The magnetic fields of other sources might affect the detections of the safety loops as well as those of the other command
and safety devices of the system.
7) Make sure the power supply to the electric motor is 230 V (50 Hz).
8)
It is recommended either of the following power supply cables:
- cable type BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the standard version,
without optional accessories;
- cable type BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the version fitted with
one optional accessory maximum (either solenoid valve, obstacle detector or heater);
- cable type BUT FLESSIBILE FG 7OR 16x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the version fitted with
two or all of the three optional accessories (solenoid valve, obstacle detector and heater);
N.W. The presence or not of the beeper on the TALOS bollard, does not affect the cable choice.
The section of the ground cable is to be chosen in compliance with the requirements of the installation site.
9) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
10) The installer shall provide the final user with information related to all of the operating commands and functions of the
system, including that concerning lowering of the post in case of an emergency (manual release operation).
11) The installer shall inform the final user of the dangers coming from the presence of persons, especially children, in the
proximity of the bollard.
12) The manufacturer reserves the right to change this manual without previous notice.
As far as configuration and execution of the system are concerned, these are to comply with the laws in the country of
installation.