![background image](http://html1.mh-extra.com/html/fadini/junior-633/junior-633_instruction-manual_3214703029.webp)
English
29
JUNIOR 633
JUNIOR 650
Connections for n° 2
Junior 633 or Junior 650
sliding gate operators
Output for courtesy
lamp relay
max 24 Vdc - 50 mA
Pedestrian input
NC contact for
2
nd
Junior input
Flashing lamp
230 Vac - 25 W max
Accessory
Electrical connections
Dip-switches and LED indication of their functions
ELECTRICAL CONNECTIONS TO THE TERMINALS AND THEIR FUNCTIONS
Carry out the following connections:
Elpro 65 MASTER
dip-switch 12 = OFF
:
terminal
15
(open)
terminal
16
(close)
terminal
17-23
(common)
terminal
22
Elpro 65 SLAVE
dip-switch 12 = ON:
terminal
4
(open)
terminal
5
(close)
terminal
3
(common)
terminal
16
(close)
terminal
17
jumper with
23
terminal
1
jumper with
2
terminal
3
(common) jumper with
6
(stop)
Master
Slave
n° 4x1
1
2
It is important to determine which Elpro 65
MASTER will command and control the Elpro 65
SLAVE. All the accessories for command,
signalling and safety must be connected to the
terminals of the Elpro 65 MASTER that manages
and controls the entire system. If the gates aren't
of the same length, the Elpro 65 MASTER is to be
mounted on the longest one.
!
Refer to the previous pages for the
dip-switch arrangements relative to the
individual accessories and functions.
!
12
DIP-SWITCH 12
ON
: Elpro 65 SLAVE (2
nd
Junior 633/Junior 650)
OFF
: Elpro 65 MASTER (1
st
Junior 633/Junior 650)
4
DIP-SWITCH 4 and 8
ON
: pre-flashing before opening
OFF
: without pre-flashing
L21, L22, L24 green = ON
with both programmers to confirm proper
communication between the two Elpro 65s
18 19
25 26
Output for courtesy lamp relay
max 24 Vdc - 50 mA
NO input for external contact for
pedestrian opening
Pedestrian trimmer
: the opening
distance of the gate is adjusted up to
3 metres.
In Automatic function (dip 3 = ON,
closes after pause time completed)
Pre-fitted jumper. NC contact for
connection to 2
nd
Junior
OUTPUT 230 Vac - 25 W max for flashing lamp
8
ON
: flasher desactivated during pause in
automatic operation (with
dip 3 = ON
)
OFF
: it flashes during pause in automatic
operation (with
dip 3 = ON
)
-
+
ELPRO 65
PROGRAMME JUNIOR MASTER AND SLAVE
SEPARATELY ONCE
THE ELECTRICAL
CONNECTIONS HAVE BEEN MADE AND THE
DIP-SWITCHES SET CORRECTLY
!
CO
MM
ON
O
PE
N
CL
O
S
E
ST
OP
A 4-wire cable is necessary for the connection
between the two Elpro 65 programmers
C
OMMO
N
PEDE
S
TRIA
N
20
23
23
22
Master
Slave
A
P
CH
C
A
P
CH
C
15 16 17
17
23
3
L24
L22
L21
20 21 22 23 24
15
1 2 3 4 5 6
16 17
L24
L22
L21
20 21 22 23 24
Summary of Contents for Junior 633