background image

Mounting and istallation manual

Sliding gate opener PULL TSA

Safety Sensor

Summary of Contents for PULL TSA

Page 1: ...Mounting and istallation manual Sliding gate opener PULL TSA Safety Sensor ...

Page 2: ...ection 15 P 4 Safety edges MSE main SSF side safety edge 16 P 5 Max force 16 P 6 ARS response time 17 P 7 Soft stop way 17 P 8 Operating mode 17 P 9 Prewarning time blinking lamp clamp 10 11 17 P A End position 17 P Reset Diagnosis 18 4 Emergency release in case of power failure note for the user 19 5 Exchange of the profil half cylinder lock 19 6 Commisioning 20 7 Status dispaly 21 8 Trouble shoo...

Page 3: ...belonging parts may not be used improperly e g for playing Furthermore handheld transmitters have to be kept in safe places and other impulse emitters as buttons and switches have to be installed out of children s reach Before beginning with the installation the installer has to make sure that all mechanical components of the gate facil ity like carrier profile rail gate frame and panels guiding e...

Page 4: ...equipment Programming display incl 20cm cable half profile cylinder with 3 keys General While developing the new operator generation Tousek PULL TSA special attention has been paid to a quick and simple instal lation and a troublefree operation together with the proven quality and reliability Accordingly many clever details have been built into the operator from the automatic learning of gate end ...

Page 5: ...lar way without undue friction or jamming along the whole travel length Make sure that there are stoppers at both ends of the track preventing the gate from running over its travel limit ATTENTION Attention Mechanial limit stops are absolutely necessary Attention The sliding gate operator PULL TSA ias been developed and designed for the automation of hori zontally travelling sliding gates Gates on...

Page 6: ... to these regulations have to be used 2 1 Installation of the motor Installation 1 lockable emergency release with optional half profile cylinder 2 gear wheel 3 cable exit 4 ground plate 4a slotted holes 4x for connection on the ground Z steel gear rack After installing the protection tubes check cable exit of operator 3 and having finished the concrete foundation the motor has to be bolted throug...

Page 7: ...ing the second meter of gear rack it is es sential to place another gear rack element under the first and second gear rack elements thereby making sure that the gearing module between the two gear rack elements will be exactly kept see illustration After installation of the gear rack please loosen the fastening bolts slightly and rise the gear rack a little along the vertical slots creating a dist...

Page 8: ...ing gate opener PULL TSA Elements of control board K Terminal blocks KM Motor clamps FE Integrated radio receiver A Antenna plug D Display plug S Sensor plug on the back side 7S 7 Segment display TA Programming buttons ESC und ENTER F Fuse 3 15A T Grounding connection Grounding The grounding connection is done in the operator housing by means of the designated grounding screw FE 7S D KM F K TA A b...

Page 9: ...ff the control cover the mains switch must be turned off If the control is power supplied its inner part is under tension In order to avoid electrical strokes the safety regula tions have to be kept The device may only be connected by trained profes sionals personal anzuschließen Theproductisnotsuitableforinstallationinexplosion hazardous areas Anall poledisconnectingmainsswitchwithacontact openin...

Page 10: ...OUNT when holding one ofthebuttonsthevalue changes automatically When pressing the button a confirmation for entering theshownmenupoint resp foracceptingtheshownvalue of a parameter is given When pressing the button you return to the superior menu point Possibly changed adjustments of a parameter are rejected with this button the former values remain valid AUTO EXIT if no button is pressed within1...

Page 11: ...er 9 stronger 7 P6 see page 17 ARS response time 0 8 0 sensitive 8 insensitive 4 P7 see page 17 soft stop way 0 9 0 x 10cm 9 x 10cm soft stop way 5 x10cm P8 see page 17 operation mode 0 1 2 3 4 5 6 7 8 9 impulse mode aut closing 5s aut closing 15s aut closing 30s aut closing 45s aut closing 60s aut closing 90s aut closing 120s aut closing 300s aut closing 600s P9 see page 17 prewarning time 0 1 2 ...

Page 12: ...s that have to be programmed within these 10 seconds The successful storage process is signaled by a rapid succession of tones Important Make a note of the memory position number shown on the display needed for deleting process transmitter list page 26 SUGGESTION with the function pro gramm impulse transmitter you can also seeonthedisplaythepositionofanalready memorized transmitter When you hear a...

Page 13: ... the impulse button Only when the gate is open it is possible to terminate the pause time by giving an impulse This causes an immediate closing movement 3 OPEN extend pause time Only opening commands are accepted from the impulse button ie it is not possible to close the gate via impulse button When the gate is open the impulse button extends the pause time The gate closes automatically after paus...

Page 14: ... 1 34 30 As impulse emitters you can use push buttons or key switches as well as external radio receivers with potential free contacts Important As stop switch a break contact has to be used If no stop switch is connected terminals 31 30 have to be wire bridged 31 30 The stop input has no emergency stop function In order to ensure the emergency stop function provide the supply line with an all pol...

Page 15: ...otor stop as long as the photocell stays interrupted After releasing the photocell the gate closes Tousek Photocell LS 180 as safety device Photocells The control unit has a power supply connection for a 24V d c photocell LS supply LS transmitter terminals 40 41 supply LS receiver terminals 40 43 Note in gate closed position the terminals 40 41 are being switched into energy saving mode no current...

Page 16: ...ACLE DETECTION when a contact strip safety edge is triggered activated then a change of direction is effected for 1 second After that the gate stops i e Hence if the safety edges have to react to obstacles during the closing movement they have to be serially connected to the terminals of the main safety edge If the safety edges have to react to obstacles during the opening movement they have to be...

Page 17: ...s 0 the motor runs to the previously learned end positions In order to have a shorter drive distance this value can be extended to up to 9 which means a reduction of approx 200mm for both final positions This adjustment is ONLY adopted when the gate is CLOSED P8 0 Impulse mode to start the closing movement of the gate an impulse given by impulse emitter is necessary 1 9 autmatic closing see table ...

Page 18: ...alculated after giving an impulse 2 Status display status display of the following inputs on certain segments of the 7 segment display Segment lights up Input OK S R ME SE I P PH D Segment doesn t light up Input triggered or not OK S Stop button I Impulse switch ME Main safety edge PH Photocell R Sensor active P Partial opening button SE Side safety edge D Display connected Status shown on the opt...

Page 19: ...riginal position i e 180 clockwise Wichtig after bringing the handle is back in normal position slowly move the gate manually in its travel direction until you can hear that the gearing has re engaged Then lock again and remove the key With the next impulse the motor searches its open position do not need to programm the end positions again 4 Emergency release in case of power failure note for the...

Page 20: ...rator again Switch on the system assuming correct connection Important the commissioning has to be carried out in impulse mode default setting and not in deadman mode 6 Commissioning Sliding gate opener PULL TSA 0 0 YES switch on confirm learn delete function confirm function NO change YES change YES detecting open position ready for operation Setting of the parameters Setting of the parameters ch...

Page 21: ...us display Sliding gate opener PULL TSA Display Meanng E P detect end position open ready H 0 gate closed H 1 gate opens H 2 gate stopped H 3 gate open H 4 gate partial opening H 5 gate closes H 8 detect open position H 9 detect closed position ...

Page 22: ...e safety sensing edge interrupted or short circuited check the correct functioning or remo ve the obstacle F 4 sensor error gate has bumped into an obstacle or is difficult to move check the force settings remove the obstacle check gate smooth opera tion F 5 a safety device or an impulse button has been triggere while detecting the end positions give another impulse F 7 receiver memory full the in...

Page 23: ...tousek EN_PULL TSA_03 25 03 2020 23 ...

Page 24: ... operated and serviced In this context please follow the EU Machine Directive accident prevention rules and laws as well as apply ing EU and national standards in force at the time of installation and operation of the gate facility The Tousek Ges m b H cannot be held responsible for any consequences resulting from disregard of applying standards and laws during installation or operation of the gat...

Page 25: ...les 4x for mounting on foundation 10 Dimensioned drawing Sliding gate opener PULL TSA We reserve the right to change dimensions and technicalspecificationswithoutpriornotice View B View A 146 5 61 254 9 270 8 210 2 22 6 4 124 1 A B 2 1 61 216 30 39 3 58 3 37 46 11 4a 3 4 gear wheel Z20M4 r44 40 30 optionaleurostandardscylinder PHZ with 3 keys art code13300220 1 2 ...

Page 26: ...List of the transmitter Sliding gate opener PULL TSA Memory position Transmitter 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 memory position Transmitter 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 ...

Page 27: ...within a reasonable time to the market surveillance authorities in response to a duly substantiated request TOUSEK Ges m b H A1230 Wien Zetschegasse 1 Österreich is authorized to compile the technical documentation The incomplete machine cannot be put into service until it is determined that the machine into which the incomplete machinehastobeinserted complieswiththetheMachine Directive 2006 42 EC...

Page 28: ... Gliwicka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 252 61 Jeneč u Prahy Průmyslová 499 Tel 420 777 751 730 info tousek cz We reserve the right to change dimensions and or technical specifications with out prior notice Claims resulting from misprints or errors cannot be accepted tousek PRODUCTS sliding gate operators cantilever systems swing gate oper...

Reviews: