background image

Dis. 

6399

meccanica

FADINI

Via Mantova 177/A - C.P. 126 - 37053 Cerea (VR) Italy -

Tel. +39 0442 330422 - Fax +39 0442 331054 - [email protected] - www.fadini.net

I

Junior 624 - Junior 633 - Junior 650

IL PROGRAMMATORE È GIÀ COLLEGATO IN FABBRICA PER IL CORRETTO FUNZIONAMENTO DEI FINECORSA, PERTANTO NON INVERTIRE
MAI FILI O CONNETTORI GIÀ INSTALLATI E COLLEGATI DALLA DITTA COSTRUTTRICE.

INSTALLATO FISICAMENTE IL JUNIOR ALLA BASE DEL CANCELLO, PROSEGUIRE CON TUTTI I DIP-SWITCH IN OFF AD ESCLUSIONE DEL DIP-
SWITCH 11 CHE IDENTIFICA L'INSTALLAZIONE DESTRA O SINISTRA. SELEZIONARE PROGRESSIVAMENTE I DIP-SWITCH DELLE FUNZIONI SOLO
DOPO AVER LETTO E  COMPRESO ATTENTAMENTE LE SINGOLE FUNZIONI SUL LIBRETTO ISTRUZIONI.

NON È GARANTITO IL FUNZIONAMENTO DEL JUNIOR CON ACCESSORI NON ORIGINALI FADINI: 

la certificazione secondo normative

EN 12445 e EN 12453 e' stata ottenuta con test di laboratorio con l'uso esclusivo degli accessori originali della MECCANICA FADINI.

In particolare il JUNIOR 624 deve essere installato solo con fotocellule FIT 55 o ORBITA 57.

DURANTE LA PROCEDURA DI APPRENDIMENTO (Fig.18-Fig.29 del Libretto Istruzioni) TUTTE LE SICUREZZE SONO DISATTIVATE

prestare quindi la massima attenzione affinchè non ci sia alcun transito nella zona di movimento del cancello.

LE ASOLE DI FINECORSA MAGNETICO HANNO I MAGNETI INTERNI GIÀ INSTALLATI CORRETTAMENTE SULLE STAFFE METALLICHE, NON APRIRLE
O INVERTIRE I MAGNETI.
DEVONO ESSERE INSTALLATE SUL LATO DESTRO E SINISTRO SULLA CREMAGLIERA, COME STAMPIGLIATO SULLA COPERTURA PLASTICA DELLE
STESSE (Fig.15 e Fig.16 a pag. 8 del Libretto Istruzioni), PENA IL NON FUNZIONAMENTO CORRETTO DELL'APRICANCELLO: IN TAL CASO
TOGLIERE IMMEDIATAMENTE IL FUSIBILE DI RETE DA 5A E RIPOSIZIONARE CORRETTAMENTE LE ASOLE.

PRIMA DI DARE TENSIONE VERIFICARE LA POSIZIONE DI MONTAGGIO DELL'APRICANCELLO "JUNIOR INSTALLATO DESTRO OPPURE SINISTRO"
VISTO ALL'INTERNO DEL CANCELLO DA MUOVERE.

Selezionare il Dip/Switch 11 a tensione assente (Fig. 4 a pag. 4 del Libretto Istruzioni): posizionare il cancello a metà corsa circa, tenere
premuto il pulsante di programmazione LP e dare tensione inserendo il fusibile di linea da 5A, quindi trascorsi 3 secondi rilasciare il
pulsante di programmazione, il led corrispondente lampeggia segnalando la modalità di apprendimento della corsa.
Premere con un impulso per 

far aprire

 il cancello e proseguire come descritto da Fig. 18 a Fig. 29 del libretto istruzioni.

IMPORTANTE: SE INVECE IL CANCELLO CHIUDE, TOGLIERE IL FUSIBILE DI LINEA DA 5A PER FERMARLO: SI E' VERIFICATO UN ERRORE DI
PARTENZA, SICURAMENTE NON SI E' SELEZIONATO LA CORRETTA INSTALLAZIONE DESTRA O SINISTRA CON IL DIP-SWITCH 11 A TENSIONE
ASSENTE. RIPETERE LA PROCEDURA PARTENDO DALL'INIZIO: IL PRIMO IMPULSO DI PROGRAMMAZIONE DEVE ESSERE SEMPRE IN APERTURA.

ALLA PRIMA ACCENSIONE VERIFICARE CHE I LED COLOR VERDE SIANO CORRETTAMENTE ACCESI; PROCEDERE POI SENZA DARE ULTERIORI
COMANDI ALLA VERIFICA DELLA LETTURA DEI FINECORSA: I LED X E Y DEI FINECORSA SI TROVANO SUL LATO DIETRO LA SCHEDA A FIANCO
IL CONNETTORE DEL FINECORSA (Fig.17).

IL DIP-SWITCH 10 DEL CONTROLLO "DSA" DELLE FOTOCELLULE DEVE ESSERE SELEZIONATO SOLO SE I TRASMETTITORI DELLE FOTOCELLULE
SONO ALIMENTATI ATTRAVERSO I MORSETTI DEDICATI 13-14 (Fig.17 DEL LIBRETTO ISTRUZIONI), PENA IL BLOCCO COSTANTE DEL CANCELLO.

!

GB

= IMPOR

T

ANTE

!

= IMPOR

T

ANT

!

Junior 624 - Junior 633 - Junior 650

THE CONTROL BOARD IS FACTORY PRE-WIRED FOR THE CORRECT FUNCTIONING OF THE LIMIT SWITCHES, NEVER CHANGE THE CONNECTIONS
OR CONNECTORS AS SET BY THE MANUFACTURER.

ONCE JUNIOR IS INSTALLED ON TO THE GATE, GO ON WITH ALL THE DIP-SWITCHES TO OFF, WITH THE EXCLUSION OF DIP-SWITCH 11 TO
BE SET TO THE INSTALLATION REQUIREMENTS EITHER RIGHT OR LEFT. THE DIP-SWITCHES ARE TO BE SET SO TO MEET THE APPLICATION
REQUIREMENTS, AFTER CORRECT UNDERSTANDING OF THEIR RESPECTIVE FUNCTIONS AS EXPLAINED IN THE INSTALLATION HANDBOOK.

THERE IS NO GUARANTEE OF CORRECT FUNCTIONING FOR JUNIOR UNLESS ORIGINAL FADINI ACCESSORIES ARE USED:

the certificate of

compliance to EN 12445 and EN 12453 norms has been obtained through lab tests only with original accessories by MECCANICA FADINI.

It is recommended that JUNIOR 624 is installed only along  the FIT 55 or ORBITA 57 photocells.

DURING THE SELF-LEARNING PHASE (Fig. 18- Fig. 29 in the installation handbook) ALL THE SAFETY DEVICES ARE OUT OF SERVICE

, make

absolutely sure that there is no transiting at all in the gate travel area.

THE MAGNETS ARE FACTORY-FITTED INSIDE THE LIMIT SWITCH METALLIC BRACKETS, DO NOT OPEN THEM OR CHANGE THE POSITION OF
THE MAGNETS.  THE BRACKETS ARE DESIGNED TO BE FIXED ON TO THE GEAR RACK TO THE RIGHT AND LEFT SIDES OF THE GATE, AS MARKED
ON THE PLASTIC COVERS OF THEM (Fig. 15 and 16 page 8 in the installation handbook), INCORRECT POSITIONING WILL RESULT INTO
FAILURE OF THE GATE OPERATOR: IF THIS IS THE CASE REMOVE THE 5A MAINS FUSE AND POSITION THE BRACKETS IN THE CORRECT WAY.

BEFORE POWERING THE SYSTEM, CHECK THE MOUNTING POSITION OF THE GATE OPERATOR “JUNIOR RIGHT OR LEFT INSTALLATION”, VIEW
THE OPERATOR FROM INSIDE THE GATE.

Set dip-switch 11 as required (Fig. 4 on page 4 in the fitting instructions manual), no power supply: drive the gate to halfway of its total
travel, press and hold the programming LP button and power the operator by fitting the 5A mains fuse. After 3 seconds release the
button, the corresponding Led flashes to indicate that gate travel learning mode is on. Give a pulse 

to open

 the gate and carry on as

described from Fig. 18 to Fig. 29 in the installation handbook.

IMPORTANT: SHOULD THE GATE MOVE TO CLOSE INSTEAD, REMOVE THE 5A FUSE TO STOP IT: A MISTAKE MUST HAVE OCCURRED ON
STARTING, YOU MUST HAVE FAILED TO SELECT THE CORRECT INSTALLATION POSITION LEFT OR RIGHT WITH DIP-SWITCH 11, IN ABSENCE
OF POWER. START AGAIN FROM THE BEGINNING: ON PROGRAMMING THE UNIT, THE FIRST PULSE MUST BE OPEN, ALWAYS.

ON FIRST SWITCHING THE UNIT ON, THE GREEN LEDS MUST BE ALIGHT; NO OTHER COMMANDS ARE TO BE GIVEN, AND CHECK THE LEDS
CORRESPONDING TO THE LIMIT SWITCHES: THE  LIMIT SWITCH X and Y LEDS ARE ON TOP SIDE OF THE PCB NEXT TO THE LIMIT SWITCH
CONNECTOR (Fig. 17)

.

DIP-SWITCH 10 “DSA” CONTROL ON THE PHOTOCELLS MUST BE ACTIVATED ONLY IF THE TRANSMITTERS OF THE PHOTOCELLS ARE POWERED
BY TERMINALS 13-14 Fig. 17 of the instructions), OTHERWISE THE SYSTEM IS TURNED INTO A PERMANENT STOP CONDITION.

1 -

2 -

3 -

4 -

5 -

6 -

7 -

8 -

!

- ATTENZIONE ! -

LEGGERE LE SEGUENTI INFORMAZIONI PRIMA DI PROCEDERE ALLA PRIMA INSTALLAZIONE

- ATTENTION ! -

READ THE FOLLOWING NOTICE BIFORE GOING ON WITH THE FIRST INSTALLATION

1 -

2 -

3 -

4 -

5 -

6 -

7 -

8 -

Summary of Contents for Elpro 62

Page 1: ...LULE SONO ALIMENTATI ATTRAVERSO I MORSETTI DEDICATI 13 14 Fig 17 DEL LIBRETTO ISTRUZIONI PENA IL BLOCCO COSTANTE DEL CANCELLO GB IMPORTANTE IMPORTANT Junior 624 Junior 633 Junior 650 THE CONTROL BOARD...

Page 2: ...45 I Libretto di istruzioni pag 1 16 GB Instructions Manual pag 1 8 17 24 F Notice de montage pag 1 8 25 32 D Betriebsanleitung pag 1 8 33 40 E Manual de instrucciones pag 1 8 41 48 NL Instructieboekj...

Page 3: ...pi ces entretoises et boulons de fixation pas compris dans le kit E Componentes principales para una instalaci n del Junior 624 en la Fig 1 1 Motorreductor deslizante electromec nico serie Junior con...

Page 4: ...de course magn tique P Pignon m4 Z18 Q Couvercle du programmateur R Transformateur 230V 24V 150VA pour Junior 624 E Lista de los componentes principales ilustrados en la Fig 2 A Luz de led azul y mbar...

Page 5: ...03A 6 Lampe clignotante Miri 4 avec antenne 7 Emetteur radio 8 S lecteur cl CHIS 37 Attention v rifier l int grit de la structure et la lin arit du mouvement du portail en liminant d ventuels frotteme...

Page 6: ...pag 5 Fig 5 Fig 6 60mm 60mm Fig 7 Fig 8 60mm 60mm...

Page 7: ...pag 6 Fig 9 96mm 96mm 60mm 96mm 60mm 2mm Fig 10 96mm 60mm 96mm 60mm 2mm 22x8 6 5 M8 96mm...

Page 8: ...pag 7 Fig 11 Fig 12 1 2 3 1 2 3 Fig 13...

Page 9: ...INKS IZQUIERDA LINKS I Finecorsa magnetico GB Magnetic limit switch F Fin de course magn tique D Magnetischer Endschalter E Final de carrera magn tico NL Magnetische eindslag I Finecorsa meccanico GB...

Page 10: ...ction wires 5A 22V 230V F2 6 3A Battery Radiocont act LED Card Elpro 62 for JUNIOR 624 24V dc Fuse terminal Output for 2 sliding leaf Elpro 62 SLAVE terminal for 2 sliding operator Dip Switch 12 ON CL...

Page 11: ...closing slow down reverse run upon contact with an obstacle and LED diagnostics Set up for double sliding exit defined by the way of Dipswitches of the RH nad LH installation Blue Amber LED lamp on th...

Page 12: ...nels All thepossible configurations are attached to their respective command accessories FADINI Output 24V FADINI FADINI Astro 43 FADINI NC NC 1 2 3 4 5 6 NC OPEN CLOSE STOP COMMON RADIO CONTACT COMMO...

Page 13: ...ro 62 MASTER Elpro 62 SLAVE Dip Switch 12 OFF Dip Switch 12 ON terminal 15 open terminal 4 open terminal 16 close terminal 5 close terminal 17 23 common terminal 3 common terminal 22 terminal 16 close...

Page 14: ...OPEN NA External clock Opening by way of external clock Connection connect the NA contact of the clock with terminal 4 OPEN and terminal 3 COMMON in parallel enabling the automatic closing with the D...

Page 15: ...Push and hold down the P botton and then afterwards install the line fuse After 2 3 seconds release the P button the LP LED will begin to flash signalling theprogramming phase 90 LP LP 3 Operation lea...

Page 16: ...onnected to the mains at the PCB IMPORTANT Once the electrical power suply has been disconnected using the unlocking key upon return of the mains electrical power the first movement of the Junior oper...

Page 17: ...mprovement TECHNICAL SPECIFICATIONS AND DIMENSIONS 316 293 140 102 62 5 40 170 38 210 95 40 170 210 296 55 290 160 Technical specifications Electrical power supply 230V 50Hz Motor voltage 24Vdc Max El...

Page 18: ......

Page 19: ......

Page 20: ...ch ohne Vorank ndigung vorzunehmen und bernimmt f r etwaige Fehler bzw Sach und Personensch den keinerlei Haftung El fabricante se reserva el derecho a aportar modificaciones al presente manual sin pr...

Reviews: