ELECTRONIC CONTROLLER FOR DARDO 430 GATE OPERATOR
ON DOUBLE SWINGING GATES
Elpro 43
GB
Meccanica Fadini s.n.c.
Responsible Manager
CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that
Elpro 43
complies with the 2006/42/CE Machinery Directive,
and also that it is sold to be installed in an “automatic system”, along with original accessories and components as indicated by the manufacturing company, that is not
liable for any possible incorrect use of the product. The product complies with the following specific norms: Low Voltage Directive 2014/35/UE, Electromagnetic
Compatibility Directive 2014/30/UE. In order to certify the product, the Manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT
NORMS.
9
TROUBLE SHOOTING IN CASE OF FAILURE
- Make sure that power supply to the controller be 230 V ±10%
- Check all the fuses
- Check the photocells contact, it must be normally closed
- Make sure that no voltage drop be occurring between the control board and
the electric motor
- Check all the NC contacts in the control board
NOTE WELL:
All the possible connections to the control board terminals are also illustrated
in the respective instructions provided with the individual accessories.
IMPORTANT FOR THE INSTALLATION AND PROPER FUNCTIONING:
- The controller is to be installed in a sheltered, dry place; holes are provided for fixing into FADINI universal box and into any commercial one.
- Make sure that power supply to the electronic controller be 230 V ±10%.
- In case of distances superior than 50 meters, increase the wire section.
- Fit the power supply to the controller with a 0,03 A, high sensibility, magneto-thermal circuit breaker.
- For the power supply, electric motor and flasher use1,5 mm² section wires up to 50 m of distance.
- For the limit switches, photocells, command switches and accessories use 1 mm² section wires.
- If no stop button is used bridge terminals 3 and 6.
N.W.: for applications such as lights control, CCTV, etc. use solid state relays to prevent interference with the microprocessor.
DIAGNOSTICS BY LEDs:
L0 (Green ON)
= Pair of photocells fitted inside, no obstacle detected
L2 (Green ON)
= Pair of photocells closing, no obstacle detected
L4
(Red OFF) = Open, switches ON when a command pulse to open is given
L5
(Red OFF) = Close, switches ON when a command pulse to close is given
L6 (Green ON)
= Stop, switches OFF when a command pulse to stop is given
L7
(Red OFF) = Radio, switches ON when a transmitter button is pulsed
and the radio contact is made on terminals 3 and 7
L9
(Red OFF) = It illuminates in case of short circuit with 24 Vdc.
It switches OFF when the short circuit fault is removed
L13 (Green ON)
= Safety edge open, switches OFF whenever the safety edge
is engaged
L14 (Green ON)
= Safety edge close, switches OFF whenever the safety edge
is engaged
L16
(Red OFF)
= Switches ON whenever a pedestrian command is given
E1 (Red ON)
= Encoder led
E2 (Red ON)
= Encoder led
General description:
the electronic controller ELPRO 43 has been designed to control the gate operator type
DARDO 430
at 230 Vac, mounted on single- or double-
swinging gates. 230 V - 50 Hz single-phase power supplied. The manufacturer is not liable for incorrect use of the controller, and reserves also the right to change and
update it to the latest standards of the art at any time.
green led, must be
ON all the time
red led OFF all the time, it goes ON
when a contact is made or a pulse given
red led ON
red led flashing:
controller on programming phase, waiting
for a pulse by the programming button
M2
M1
TRANSFORMER
1 2 3 4 5 6 7 8 9 10
PLUG-IN
RADIO
CARD
CONNECTOR
phot
oc
ells
closing
radio c
o
ntac
t
common
open
close
st
op
24
V light max 3
W
24 V
dc
output
(max load 500 mA:
n° 1 radio r
e
ceiv
er
n° 3 pairs of phot
oc
ells)
12 V
dc
output
elec
tric lock
230 Vac
flasher OUTPUT
max 25W
SINGLE-PHASE
PCB power supply
230 V - 50/60 Hz ± 10%
24 V
ac/dc
output
f
or phot
oc
ell
T
X
enabled t
o
DSA c
o
n
tr
o
l
NC
NEUTRAL
LIVE
ELPRO 43
E 43
L0
L2
L4 L5 L6 L7
L10
FORCE
DURING
TRAVEL
DWELL
TIME
1 s - 220 s
FORCE
DURING
SLOWDOWN
-
+
-
+
-
+
NC
Capacitor
M1 Motor
12,5 μF
Capacitor
M2 Motor
12,5 μF
11 12 13 14 15 16 17 18
A1 C1 B1 A2 C2 B2 19 20
D1 E1 F1 D2 E2 F2
L13 L14
L16
saf
et
y edge open
co
mmon
saf
et
y edge close
8,2 kΩ or NC
8,2 kΩ or NC
pedestrian
E1
E2
21 22 23
GROUND
ENCODER
M1
ENCODER
M2
F1 = 5 A
GENERAL
FUSE
Programming
button
LP
2
nd
pair
phot
oc
ells
OVERLOAD
com.
com.
ON
OFF
1
2
3
4
5
6
7
8
9 10 11 12