ELECTRONIC CONTROLLER FOR DARDO 430 GATE OPERATOR
ON DOUBLE SWINGING GATES
Elpro 43
GB
10
Dip-Switches
1 =
OFF
Photocell. No stop in opening
2 =
OFF
Radio contact 3-7 stop and reverse in opening
3 =
OFF
Semiautomatic functioning
4 =
OFF
No pre-flashing before opening
5 =
OFF
Radio contact 3-7 reverse on each pulsing
6 =
OFF
7 =
OFF
No stroke reversing pulse in opening.
8 =
OFF
Flasher (contact 19-20) ON in dwell time.
9 =
OFF
No reclosing after crossing the photocells
10 =
OFF
No photocell DSA control before any operation
11 =
OFF
Blank
12 =
OFF
Blank
1 =
ON
Photocell. Stop in opening
2 =
ON
Radio contact 3-7 no stop and no reverse in opening
3 =
ON
Automatic closing after dwell time
4 =
ON
Pre-flashing before gate starts
5 =
ON
Radio contact 3-7 step by step: open-stop-close-stop
6 =
ON
Blank
7 =
ON
Stroke reversing pulse for 2 s is enabled in opening
8 =
ON
Flasher (contact 19-20) OFF in dwell time.
9 =
ON
Reclosing after crossing the photocells (
Dip 3= ON
)
10 =
ON
Photocell DSA control before any operation
11 =
ON
Blank
12 =
ON
Blank
ON
OFF
123
4
5
6
7
8
9
1
0
1
1
1
2
DIP
-SWIT
CH
All the possible connections to the control board terminals are also illustrated in the instructions provided with the individual accessories.
NOTE WELL: THE INSTALLATION OF NON FADINI ORIGINAL ACCESSORIES MAY DAMAGE THE PC BOARD. MAKE
SURE THAT DRY CONTACTS BE ALWAYS USED FOR THE NO-NC INPUTS. BRIDGE ALL THE NC CONTACTS NOT IN USE.
!
!
common
common
open
close
st
op
+
+
ON
: stop in opening and reverse in closing once
obstacle is removed
OFF
: no stop in opening and reverse in closing
when obstructed
ON
: no stop and no reverse in opening
OFF
: stop and reverse in opening on pulsing
L7 red OFF
= no RADIO contact,
it goes ON whenever a radio pulse is given
ON
: step by step with stop in between
OFF
: gate travel reverse on radio pulsing
L4 red OFF
= no OPEN contact,
it goes ON whenever an open pulse is given
L5 red OFF
= no CLOSE contact,
it goes ON whenever a close pulse is given
L6 green ON
= STOP contact closed,
it goes OFF whenever a stop pulse is given
By any NO connection to these two terminals
the following is performed, on each pulsing:
- Opening only:
Dip 2=ON and Dip 5=OFF
- Travel reversing on each pulsing
Dip 2=OFF and Dip 5=OFF
- Step by step operations:
open-stop-close-stop
Dip 2=OFF and Dip 5=ON
DIP-SWITCH N° 1:
DIP-SWITCHES N° 2 and 5 (do NOT set both of
them to ON at the same time):
2
5
1
Radio contact:
Keyswitch:
Photocells:
DGT 61
Main PCB
Chis 37
Fit 55
Trifo 11
Sape 69
Receiver
Chis E 37
Orbita 57
Receivers:
Astro 43,
Jubi 433,
Siti 63, Birio 868, VIX 53
RADIO
CONTACT
inner
NC
NC
NC
NC
NC
outer
+
Accessory
Electrical connections
Dip-switch and LED indication
of the various functions
View from inside property:
Outer photocells:
all the
NC contacts
of the receivers of the outer
photocells are to be
series
connected to
terminals
1
and
2
: on being engaged, in closing
phase, gate travel is revered to open.
Inner photocells:
all the
NC contacts
of the receivers of the inner
photocells are to be
series
connected: on being
engaged, gate travel is stopped in opening,
closing and dwell time untill cleared.
NO and NC contacts to be connected to the
respective terminals of the key- or
button-operated switches.
All possible configurations are in the
instructions attached to the specific
command accessory.
F
3 4 5 6
3
-
Output provided in case a light be required to indicate
gate status:
Light
ON
= gate open
Light
OFF
= gate closed
Flashing
0,5 s (fast)
= gate closing
Flashing
1 s (normal)
= gate opening
24 V - max 3 W
pilot light
output:
+
8 9
7
F 1 2
L2 green ON
= no obstacle between outer
photocells,
it goes off when an obstacle is detected
L0 green ON
=
no obstacle between innner
photocells,
it goes off when an obstacle is detected
Summary of Contents for Elpro 43