background image

!

Drwg. No.

4135

5

PLUS

10

GB

SINGLE- AND THREE-PHASE FOR SLIDING GATES
AND AUTOMATIONS FITTED WITH LIMIT SWITCHES

In case of failure of the panel:

- Make sure that the power supply to the electronic programmer is

230V 

±

10% or 400V 

±

10%

- Make sure that the power supply to the Electric Motor is 230V 

±

10%

or 400V 

±

10%

- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control panel to

the electric motor

General description:

 the electronic control panel Elpro 10 Plus, new generation, is designed to operate sliding gates. Power supply is 230/400V single-phase and three-

phase. Built in full compliance with 2006/95/CE Low Voltage and 2004/108/CE - 92/31/CEE Electro-Magnetic Compatibility Regulations. Fitting operations are recommended
by a qualified technician in conformity to the existing safety standards.The manufacturing company declines any responsability for incorrect handling and application; also,
it reserves the right to change or update the control panel any time. 

Failure to follow installation regalations may result into serious damage to property and persons.

PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Make sure that the power supply to the electronic programmer is 230V 

±

10% or 400V 

±

10%

- Make sure that the power supply to the Electric Motor is 230V 

±

10% or 400 V 

±

10%

- For distances of over 50 metres we recommend using  electric cables with bigger sections.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5 mm

2

 section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m.Use 1 mm

2

 section wires for limit   

switches, photocells, push-buttons/key-switch and accessories.

- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.

DIP-SWITCH

1

4 5 6 7 8

2

ON

OFF

3

Dip-Switch:

1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Deadman Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. Blank

Led Status Indication:

L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate moving
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
L10= It stays on for a time equal to the time set on T4 Trimmer

T

S

R

PULIN 3

26

27
28

3

DIP-SWITCH

ON

OFF

1

4 5 6 7 8

2 3

L2

L3

L4

L5

L6

L7

L8

L9

1

7

4

10 11 12 13

19

20

2

8

5

3

9

6

STOP

COMMON

OPEN

CLOSE

230V 25W max

FLASHING LAMP

230/400V

L1

L10

F1=8A mains

F2=8A mains

F3=8A mains

F5=1A flashing lamp

protection

F4=630mA

Transformer

protection

F6=2A

24V protection

RADIO
PLUG-IN
CARD CONNECTOR

MOTOR RUN TIME
from 5 to 128s

DWELL TIME
from 5 to 128s

PEDESTRIAN
OPENING TIME
from 3 to 30s

-

+

-

+

-

+

-

+

EXT TIME (electric lock and
courtesy light) from 2 to 255s

T4

T3

T2

T1

PHOTOCELLS

SAFETY EDGE

RADIO

LIMIT SWITCH CLOSE

LIMIT SWITCH OPEN

COMMON LIMIT SWITCH

ELPRO 10 PLUS

18

16

17

COMMON

M

U

W

V

21

22

NEUTRAL

S

LIVE

23

22

ELECTRIC LOCK OR

12V AC RELA

Y FOR

230V COUR

TESY LIGHT

RS RS

CAPACITOR

LIVE

24V OUTPUT max. load:

2 pairs photocells

1 radio receiver

LIVE

R

TRANSFORMER

230V 

±

10% 50Hz

SINGLE-PHASE

VOLTAGE SUPPLY

400V 

±

10% 50Hz

THREE-PHASE

VOLTAGE SUPPLY

NEUTRAL

ELPRO 10 plus

MICROPROCESSOR

LIVE

MOTOR

230V
400V

®

Reviews: