background image

Drwg. No.

4135

6

PLUS

10

GB

SINGLE- AND THREE-PHASE FOR SLIDING GATES
AND AUTOMATIONS FITTED WITH LIMIT SWITCHES

Photocells and Safety Edge:

PHOTOCELLS AND
SAFETY EDGE

12 13

24V (500 mA) OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)

Push Button Switch Pulin 3:

26

27

28

3

COMMON

Led to indicate status of Open - Stop -
Close switches

Electric lock:

Set the T4 Trimmer Time to the lowest value
The electric lock is excited for 2 seconds

1

DIP-SWITCH 1:

ON: Photocells stop gate while opening,
       reverse it on closing once obstacle is
       removed

OFF: Photocells do not stop gate while
        opening, reverse it on closing in
        case of an obstacle

Button switch:

3

4

5

6

STOP

COMMON

OPEN

CLOSE

Limit switch:

10

COMMON

8

9

LIMIT SWITCH

CLOSE

LIMIT SWITCH

OPEN

Radio Contact:

7

3

COMMON

RADIO

CONTACT

- Open/Close (Standard)
- Travel reversing on pulsing
- Step by step

2

5

ON: Step by step. Stop in between

OFF: Standard operating mode

ON: Gate is not reversed while opening

OFF: Any pulse reverses the gate

DIP-SWITCH 2 and 5 (NEVER set BOTH of them to ON at the same time):

24V 3W Indication Light:

Light 

ON

 = Open gate

Light 

OFF

 = Closed gate

Flashing 

(fast) 0.5s

 = Closing gate

Flashing 

(normally) 1s 

= Opening gate

Flashing 

(slowly) 2s

 = gate is stopped

3

11

Connect a 24VAC Modular Relay
(T4 Trimmer Time from 2s to 255s)
to operate a 230V lamp

Courtesy light:

1

2

RS RS

RS RS

-

+

- TIME EXT (Electric lock and

courtesy light) from 2 to 255s

T4

-

+

T4

LOW VOLTAGE ELECTRICAL CONNECTIONS

®