Single- (230V) and Three-phase (400V) Motors:

-

+

T1

MOTOR RUN TIME

OPEN / CLOSE
from 5 to 128s

T2

-

+

CAPACITOR

18

16

17

COMMON

M

MOTOR

U

W

V

Flashing lamp:

19 20

 230V MAX 25W

4

7

DIP-SWITCH 4 and 7:

ON: Pre-flashing

OFF: No pre-flashing

ON: Lamp is not operating during

Dwell Time. Automatic Mode.

OFF: It flashes during Dwell Time .

Automatic Mode.

230V

400V

Power supply:

Hold on switched (Deadman) control:

Open and Close operations are achieved "by holding a switch on"
(no relay self-holding is involved) therefore a phisical attendance
is required to keep the gate opening or closing until either the
button or key is released.

DIP-SWITCH 6

6

ON= Deadman Control. Dip-switch 4=OFF

and Dip-switch 3=OFF

OFF= Standard Operations

Remote Controlled Operations Excluded during Dwell Time on Automatic Mode:

3

ON= Automatic Closing

OFF= Closing by Pulse

5

ON: Step by step. Stop in between

OFF: Standard Operations

With this setting it is not possible to operate the gate by remote control during the dwell time on automatic mode.
DIP-SWITCH 2=ON, 3=ON and 5=ON

2

ON: No reversing on opening

OFF: Travel reversing on any pulsing

3

DIP-SWITCH 3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

Automatic / Semiautomatic:

Automatic Operation: 

any pulse opens the gate, the gate stays open as long as the Dwell time

expires as set by T2 trimmer, then it closes automatically, no pulsing is required.

Semi-automatic Operation: 

any pulse opens the gate that stays open. A second pulse to Close is

required for the gate to close.

Dwell Time

from 5 to 128s

T2

-

+

Pedestrian Opening:

-

+

Trimmer T3 to the lowest disactivates Pedestrian Opening
From 3 to 30s it can be activated by any pulse (eg. by remote control) superior to 2s

How it works: Set the clock to the required time. On the pre-set time the gate is automatically opened and held open. Any further
pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and
after the pre-set dwell time the gate is closed automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.

Time clock installation:

DIP-SWITCH No.3=ON Automatic Closing

3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic

closing by pulse

-

+

Pedestrian Trimmer 

T3

set on to zero

4

3

COMMON

COMMON

OPEN

NO

External Time Clock

PLUS

10

GB

7

4135

Drwg. No.

SINGLE- AND THREE-PHASE FOR SLIDING GATES
AND AUTOMATIONS FITTED WITH LIMIT SWITCHES

OPERATING MODES

FADINI

l'apricancello

ELECTRICAL POWER CONNECTIONS

T3

PEDESTRIAN TIME

from 3 to 30s

230V 

±

10% 50Hz

SINGLE-PHASE

21

22

NEUTRAL

S

LIVE

23

22

R

21

22

T

R

S

LIVE

23

22

400V 

±

10% 50Hz

THREE-PHASE

LIVE

NEUTRAL

®

Dwell Time

from 5 to 128s