background image

CONNECTING GATE LEAF TO THE JACK AND SETTING INTO OPERATION

Once satisfied that corner fixing and jack positioning at the foot of the gate have been completed, next step to carry out is fixing 
the gate to the jack square shaft by means of the ferrule supplied with the equipment and a plate to weld (not included as it 
depends on gate type and thickness).
First operation: rotate the jack square shaft to the end of the permitted turning by a wrench (no effort is required in doing this as 
there isn’t any oil yet inside at this stage).

Once satisfied the jack is leveled (by the adjusting screws in the galvanized base plate), fit the ferrule (F-ring) with square hole on 
to the jack shaft and then weld it to the reinforcement plate (not in the equipment), and this one to the gate foot.

Pic. 7

Pic. 8

Pic. 9

English

N° 4 adjusting 

screws to 

make level

Shaft rotated to the end of 

the closed limit position 

Shaft rotated at least 5°

back against end of closed limit position

Weld the plate to the 

gate foot with the 

gate in closed 

position

Weld the plate to the

ferrule with square hole

IMPORTANT: for the gate to stay securely closed in position, once satisfied the previous step is carried 
out all right, rotate the shaft back by at least 5°.

!

IMPORTANT: before final fixing can be carried out, it is advisable that 
a temporary set up be provided to allow trial open and close by hand.

!

Underground oil-hydraulic operator with separate motor-pump

DRIVE 700

GREASE

7

istr_drive700_GB.ai   7   10/05/2022   15:15:51

Summary of Contents for DRIVE 700

Page 1: ...EN 13241 EN 12453 EN 12445 DRIVE 700 Underground oil hydraulic automation with separate motor pump assembly for swinging gates 1 16 GB Instructions manual pages the gate opener...

Page 2: ...rian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gate war...

Page 3: ...the gate s in case this option is mounted Being an oil hydraulic product it has therefore all the advantages this kind of operators have such as reliability smooth movements and adjustable thrust pow...

Page 4: ...tor pump unit or in case of gate leaves wider than 2 meters 12 Photocell transmitter 13 Keyswitch 14 Gate stop in closed position 15 Radio transmitter Pic 2 Indicative layout it is the installer s res...

Page 5: ...rete casting Draining pebbles Soakaway tube 13 cm 58 60 mm 6 5 cm IMPORTANT the position of the ground foundation box is in relation to the position of the upper hinge The center of the hole in the fo...

Page 6: ...onnections Weld the 4 corner plates supplied with the equipment onto the anchoring plate to take the jack galvanized base making sure that the jack be in the correct position for its center line to co...

Page 7: ...t the ferrule F ring with square hole on to the jack shaft and then weld it to the reinforcement plate not in the equipment and this one to the gate foot Pic 7 Pic 8 Pic 9 English N 4 adjusting screws...

Page 8: ...s one to lead oil pipes to Drive 700 Estru motor pump and a duct to drain fluids away Once all the required ducts have been laid firmly set the aluminium foundation box by concrete Pic 10 Pic 11 Engli...

Page 9: ...ll the funnel out and turn it upwards as described in Pic 13 Pic 12 Pic 13 English Drive 700 jack Drive 700 Estru motor pump IMPORTANT any bending of the copper pipes is to be smooth and free from sha...

Page 10: ...re to be connected to the jack in view of the following red screw controls pressure in closing green screw controls pressure in opening Pic 15 Red screw to adjust force in closing Clockwise pressure A...

Page 11: ...of the jack shaft Only the speed can be controlled but not the position when slowdown starts Control is by the screws that are incorporated in the jack end castings Turning clockwise speed is decrease...

Page 12: ...r gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and re...

Page 13: ...Underground oil hydraulic operator with separate motor pump DRIVE 700 English 13...

Page 14: ...English Underground oil hydraulic operator with separate motor pump DRIVE 700 14...

Page 15: ...Oil volume in the jack 0 25 dm Motor pump static weight 8 kg Weight of jack with accessories 16 kg Max gate weight per leaf 700 kg Max gate width per leaf 4 m Protection standard IP 67 A 40 C with sp...

Page 16: ...IALS ARMFUL TO THE ENVIRONMENT 20220510 100 1 2 3 4 200 300 400 500 600 700 MAX GATEWIDTHPERLEAF m MAX GATE WEIGHT PER LEAF kg The gate structure design solid in filled height and strong wind pressure...