For those installations where one or two magnetic loops are required, it is recommended to
follow the instructions included with the detector (Ref. drwg. 7038).
Ceiling
5 cm
1.090
900
840
24 cm
Hinge
Barrier beam
B
Barrier beam
A
H
C = A + B
L
The B barrier beam is provided in lengths of 2,10 metres or
3,20 metres according to width C as required.
Where C is the sum of A+B.
In case a BAYT 980 with articulated arm is required at the
time of the order, it comes factory-preset for it
(Ref.
Drawing 5257).
9
English
BAYT 980
Pic. 15
Pic. 16
ATTACHMENT OF THE HINGED BARRIER BEAM TO THE HOUSING CABINET
According to the demands of the installation it is possible to apply a hinge coupling to Bayt 980 following the instructions in
Pic. 15.
INSTALLATION OF THE BAYT 980 WITH MAGNETIC LOOP
Ceiling
height
H
2,50 m
2,70 m
2,80 m
3,00 m
3,70 m
4,10 m
Barrier beam
length
A
1,60 m
1,80 m
1,90 m
2,10 m
2,80 m
3,20 m
Opening
time
4 s
4 s
4 s
8 s
8 s
8 s
Metal cable fixed length
(supplied by the manufacturer)
L
1,25 m
1,45 m
1,55 m
1,75 m
2,45 m
2,85 m
Ref. code 2037L - 6 m circumference,
pre-assembled loop.
Ref. code 2042L - 12 m circumference,
pre-assembled loop.
Ref. code 2037L - 6 m circumference,
pre-assembled loop.
Ref. code 2042L - 12 m circumference,
pre-assembled loop.
Bayt 980
Obstacle presence detector
Magnetic loop power supply
cable, total length =
10 metres from the detector
Magnetic loop power supply
cable, total length =
10 metres from the detector
oil-hydraulic barrier