background image

English

BAYT 980

oil-hydraulic barrier

Via Mantova, 177/A - 37053 Cerea (VR) Italy 
Ph. +39 0442 330422 

Fax +39 0442 331054

[email protected] - www.fadini.net

GB

2012/19/UE

 Directive

Re. disposal of electric

and electronic waste

DISPOSE PROPERLY OF MATERIALS

ARMFUL TO THE ENVIRONMENT

TECHNICAL SPECIFICATIONS

ELECTRIC MOTOR

Power yield 

 

                     0,37 kW (0,5 HP)

Absorbed power   

                     510 W

Frequency 

 

           

  50 Hz

Supply voltage 

 

                     230 Vac

Absorbed current   

                     2,4 A

Capacitor  

 

                     25 μF

Motor rotation speed 

 

  1.350 rpm

Intermittent service 

 

  S3

Electric cable 

 

                     H05VV-F

OIL-HYDRAULIC MOTOR-PUMP UNIT - COS 982 -

Working pressure   

 

         20 atm

Max. pressure 

 

 

         40 atm

Pump 

 

 

 

         P6 - P8 - P16

Oil type   

 

 

         Oil Fadini - Item 708L

Reservoir capacity   

 

         2,5 liters

Static weight 

 

 

         22,5 kg

Working temperature 

 

         -20 °C +80 °C (*)

Protection standards 

 

         IP 65 (inside the housing)

(*) -40 °C with specific optional accessories (Ref. General Catalogue).

Housing weight (without beam) 

  75 kg

Colour of the housing 

              RAL 2002 Orange Red 

(for Bayt 980 painted)

Door and top colour   

              Metallic grey, orange peel finish 

(for Bayt 980 painted)

Housing, door and top 

              Aisi 304 inox, brushed 

(for Bayt 980 stainless steel)

PERFORMANCE

 (4 s - 4,20 m beam)

Frequency of use   

 

         very intensive

Service cycle 

 

 

         opening       4 s

 

 

 

 

         dwell             4 s

 

 

 

 

         closing          4 s

 

 

 

 

         dwell             4 s

Complete cycle time 

 

         16 s

Complete cycles
opening-dwell-closing-dwell 

         No. 225/hour

Annual cycles (with 8 hours of use per day) No. 657.000

PERFORMANCE

 (8 s - 6,40 m beam)

Frequency of use   

 

         very intensive

Service cycle 

 

 

         opening       8 s

 

 

 

 

         dwell             4 s

 

 

 

 

         closing          8 s

 

 

 

 

         dwell             4 s

Complete cycle time 

 

         24 s

Complete cycles
opening-dwell-closing-dwell 

         No. 150/hour

Annual cycles (with 8 hours of use per day) No. 438.000

PERFORMANCE

 (14 s - 6,40 m beam with fence)

Frequency of use   

 

         very intensive

Service cycle 

 

 

         opening     14 s

 

 

 

 

         dwell              7 s

 

 

 

 

         closing        14 s

 

 

 

 

         dwell              7 s

Complete cycle time 

 

         42 s

Complete cycles
opening-dwell-closing-dwell 

         No. 86/hour

Annual cycles (with 8 hours of use per day) No. 251.000

PERFORMANCE

 (19 s - 8,50 m beam with fence)

Frequency of use   

 

         very intensive

Service cycle 

 

 

         opening      19 s

 

 

 

 

         dwell            10 s

 

 

 

 

         closing         19 s

 

 

 

 

         dwell            10 s

Complete cycle time 

 

         58 s

Complete cycles
opening-dwell-closing-dwell 

         No. 62/hour

Annual cycles (with 8 hours of use per day) No. 181.000

2018/10

PRODUCT SPECIFICATIONS

Oil-hydraulic road barrier with traffic stopping beams whose length range is 3 m to 8 m, very heavy duty. Oil-hydraulic unit 
consisting of one motor pump assembly incorporating a piston actuator. Suitable for applications in private, commercial 
industrial areas, car parks and urban applications. IP65. Overall dimensions 350 x 305 x H 1.090 mm. Anodized aluminium 
beam, oval section. Reinforced, S235JR steel structure, cataphoresis treated and powder coated. Available in AISI 304 
brushed stainless steel. Incorporated control board. Opening time from 3 s to 19 s, depending on beam type. Frequency of 
use 3.000 cycles/day (version 8 s). Supply voltage 230 Vac ± 10%, 50 Hz. Absorbed power 510 W. Working temperature -40 °C 
+80 °C. Beam options available with incorporated high visibility LEDs, fence, articulated joint (for installations with ceiling 
limitations), swing away arm system in case of impact with a vehicle. Manual release device inside the housing.

INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM

1) Make sure the site is free from utilities that may interfere with it.
2) Make sure the power supply to the electric motor is 230 V (50 Hz).

The section of the ground cable is to be chosen in compliance with the requirements of the installation site.
As far as configuration and execution of the system are concerned, these are to comply with the laws in the country of 
installation.

Summary of Contents for BAYT 980

Page 1: ...to 8 metres Stainless steel and painted versions Version with aluminium fence Version with articulated beam Folding or fixed leg with forked end Fully convertible into right or left versions Pre set...

Page 2: ...edestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gat...

Page 3: ...p of two modules 2 10 m 3 20 m 9 Folding leg optional 10 Fixed pedestal with beam catcher optional Bayt 980 internal view Left LH Bayt 980 internal view Right RH MAIN ELEMENTS FOR THE INSTALLATION OF...

Page 4: ...FOR TWO BARRIERS For installations that require two Bayt 980 roadway barriers it is necessary to arrange an underground electrical conduit between the two housing cabinets for the connection of the ph...

Page 5: ...o the ground it is necessary to wait until the concrete has hardened the Bayt 980 housing cabinet can be mounted onto it and then the four M14 hexagonal nuts can be securely tightened with their respe...

Page 6: ...ion of 1 mm will have to be utilised for a maximum distance of 50 metres For distances longer than 50 metres it is recommended that cables with sections suitable for a proper standard of installation...

Page 7: ...in order to fit the beam Beam clamp with 8 attachment screws R532 aluminium barrier beam Led signal lamp always lighted R532 aluminium barrier beam Loosen the screws located underneath the coupling c...

Page 8: ...RWEIGHTS ON THE BAYT 980 In Bayt 980 installations with beams that are 6 40 metres in length or longer and fittted with a fence it is necessary to also attach counterweights by means of nuts bolts and...

Page 9: ...allation it is possible to apply a hinge coupling to Bayt 980 following the instructions in Pic 15 INSTALLATION OF THE BAYT 980 WITH MAGNETIC LOOP Ceiling height H 2 50 m 2 70 m 2 80 m 3 00 m 3 70 m 4...

Page 10: ...essary to remove the protective covers 22 unscrewing the M8 nut 20 from inside of the cabinet and then removing the stop plate 21 Pic 19 The housing cabinet is in this way prepared for the attachment...

Page 11: ...use 1 A Red Yellow Green 27 28 29 23 24 27 28 29 23 24 PHASE External power supply 230 V 50 Hz Drive unit COS 982 PHOTOCELL AND SAFETY EDGES Red Yellow Green Common External 230 V 50 Hz electrical pow...

Page 12: ...rminals of the Elpro 980 master respectively with the 3 4 5 terminals of the Elpro 980 slave Elpro 980 master PCB Elpro 980 slave PCB 63 64 65 66 60 61 Fuse 1 A Red Yellow Green 1 2 3 4 5 6 7 8 9 10 1...

Page 13: ...6 lock nut d previously loosened must be tightened so as to lock the fork to the Bayt 980 base 5 Unscrew the closing limit switch feeler a until the micro switch snaps when the beam is in horizontal p...

Page 14: ...l position It is recommended that the limit vertical position is adjusted beyond 90 in this way the limit switch feeler is caused to operate before the very end of the permitted stroke 3 Micro switch...

Page 15: ...ecific unlocking spanner to release turn the release spanner in an anti clockwise direction max 1 2 turns Important at the moment of the first running test at the factory the thrust force is calibrate...

Page 16: ...n series or all flashing simultaneously Pic 29 English BAYT 980 Pic 28 Pic 29 max 460 mm 510 8 100 max net length Important dimensions are variable based on the number of counterweights attached See t...

Page 17: ...4 80 354 FRONT M14 510 260 135 150 150 net length 200 135 65 3 370 2 100 300 100 3 200 Pic 30 In zinc coated iron Weight 10 kg each Zinc coatedorstainlesssteelversion Zinc coatedanchorbolts M14x200 In...

Page 18: ...Pump Fence Cable KIT Beam length m Applications Leds 18 COS 982 HYDRAULIC DRIVE UNIT OVERALL DIMENSIONS English BAYT 980 Pic 31 66 230 mm 180 140 370 110 345 250 160 blue brown black yellow green Imp...

Page 19: ...g away of the beam in the direction of the impact with a vehicle and has been designed to protect the main structural components of BAYT 980 barrier and beam Following an impact it is required that th...

Page 20: ...100 10 10 1 2 3 Beam HOW TO FIX THE BEAM TO ALA 180 SWING AWAY SYSTEM E6 Pic 35 Once the beam is well fitted in tighten hard the screws of the joint Before tightening M10 screw and locknut make sure...

Page 21: ...BAYT 980 M10 M10 1 2 3 4 5 6 Before tightening M10 screw and locknut make sure the beam is perpendicular vertical in opening M10 M10 M6x14 INOX E5 BRINGING BACK ALA 180 SWING AWAY SYSTEM TO ORIGINAL P...

Page 22: ...22 English oil hydraulic barrier BAYT 980...

Page 23: ...per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation mai...

Page 24: ...ice cycle opening 14 s dwell 7 s closing 14 s dwell 7 s Complete cycle time 42 s Complete cycles opening dwell closing dwell No 86 hour Annual cycles with 8 hours of use per day No 251 000 PERFORMANCE...

Reviews: