10
PROCEDURE FOR DRILLING AND ATTACHING THE MIRI 4 FLASHER ON THE CABINET COVER
• Loosen and remove the three M8 attachment screws (
9
and
16
) of the cabinet cover (
6
) - Pic. 18.
• Turn the cover (
6
) upside down and drill a 4,2 mm diameter hole in it and thread M5 the three studs (
24
) for the attachment of
the Miri 4 flasher (
1
). Pic. 17.
• The central stud of the cover (
23
) must be drilled out with a 10,5 mm diameter bit to enable the passage of the electrical power
supply cable for the Miri 4 flasher and for the possible insertion of the RG58 coaxial cable for the Birio A8 aerial - Pic. 17.
• Then run the electrical cables through the central 10,5 mm diameter hole and attach the vertical coupling (
5
) of the Miri 4 flasher
(
1
) with the three M5 screws (
4
) on the outside of the cover - Pic. 18.
• Replace the cover on the housing cabinet (
17
) and attach it with the three M8 screws so as to cover the Bayt 980 cabinet, as shown
in Pic. 18.
In order to install the Fit 55 photocells and the Chis 37 key-switch on the housing cabinet
, it is necessary to remove the
protective covers (
22
) unscrewing the M8 nut (
20
) from inside of the cabinet and then removing the stop plate (
21
) - Pic. 19.
The housing cabinet is in this way prepared for the attachment of all of the operational accessories - Pic. 18.
English
BAYT 980
Pic. 18
Pic. 17
Pic. 19
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
23
24
17
18
19
22
20
21
VIEW OF THE COVER FROM BELOW
n° 4x1
n° 4x1
1. Miri 4 flasher with Birio A8 aerial (optional)
2. Miri 4 flasher cable with 2x1,5 wires
3. RG58 aerial cable
4. M5 screws (3 pieces)
5. Vertical coupling for Miri 4
6. Cover to disassemble, once the three attachment screws
for the Bayt 980 are removed
7. Control box with Elpro 980 electronic programmer
8. Limit switch with spring feeler
9. M8x16 TSEI Stainless Steel screws (2 pieces)
10. Limit switch cover
11. M6x25 TEI galvanised screw (1 piece)
12. Limit switch spring
13. Door lock
14. Door
15. Cabinet door switch for general electrical power disconnection
16. M8x16 TBEI Stainless Steel screw (1 piece)
17. Bayt 980 housing cabinet
18. Chis 37 key- switch (optional)
19. Fit 55 photocell (optional)
20. M8 nut
21. Lateral cover stop plate
22. Protective lateral cover
23. Ø 10,5 central stud drill hole
24. Ø 4,2 - 3 studs drill holes
oil-hydraulic barrier