BARRI 88

E

n

g

li

sh

Oil-hydraulic road barrier with beam of 4 meters

Summary of Contents for BARRI 88

Page 1: ... 12 GB Instructions manual pages Oil hydraulic road barrier for 4 meters gateways Left and right handed versions Folding or fixed pedestal options Adjustable slowdown in opening and closing option with articulated arm thegateopener ...

Page 2: ...ate is equipped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gate warning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical do...

Page 3: ...ulic actuator 4 Main assembly motor pump actuator 5 Pressure control valves 6 Balance spring 7 Anchoring base plate with hook bolts 8 Emergency release 9 Elpro 88 control board 10 Control board support arm 11 Beam limit switch assembly with adjustment screws 12 80x30 L 4 m beam 13 Folding pedestal 14 Fixed pedestal optional Barri 88 Left Sx Barri 88 Right Dx BARRI 88 Entry side Entry side Oil hydr...

Page 4: ... power supply to the installation command and safety accessories as illustrated in Pic 4 FITTING THE BEAM English Pic 4 Pic 5 Important before cementing the anchoring base plate drive the 2 bolts thoroughly out to the end of the thread Important by means of a spirit level make sure the anchoring base plate be perfectly flat in both directions it is also recommended that it be 5 mm higher than the r...

Page 5: ... THE POST SUPPORTING THE PHOTOCELL FIXED PEDESTAL INSTALLATION 5 English Pic 6 Pic 7 TRIFO 11 BARRI 88 Ø 30 Ø 30 Ø 30 Junction pit Post mounted with TRIFO 11 photocell Oil hydraulic road barrier with beam of 4 meters ...

Page 6: ...technical data section in this manual to be filled in in compliance with the EN 12445 and EN 12453 regulations For power supply electric motor and flasher 1 mm square section cables are to be used up to 50 meters of distance For longer distances suitable cables are to be used following the standards of a good technical installation Electric cables having wires of 0 5 mm square section are to be used...

Page 7: ...crews Pic 10 SLOWING DOWN AT END OF MOVEMENTS BARRI 88 BARRI 88 LEFT BARRI 88 RIGHT Pic 10 UNSCREW ADJUSTMENT LOCK TIGHTEN ADJUSTMEN LOCK LIMIT SWITCH ADJUSTMENT HORIZONTAL BEAM LIMIT SWITCH ADJUSTMENT HORIZONTAL BEAM LIMIT SWITCH ADJUSTMENT VERTICAL BEAM LIMIT SWITCH ADJUSTMENT VERTICAL BEAM 1st OPERATION 2nd OPERATION 3rd OPERATION Pic 11 SLOWDOWN SETTING OPENING BARRI 88 RIGHT SLOWDOWN SETTING ...

Page 8: ... 88 LEFT BARRI 88 RIGHT green screw POWER CONTROL OPENING red screw POWER CONTROL OPENING red screw POWER CONTROL CLOSING green screw POWER CONTROL CLOSING max 1 2 turns less power more power less power more power Pic 14 GREASE PERIODICALLY ONCE A YEAR AT LEAST Oil hydraulic road barrier with beam of 4 meters ...

Page 9: ...s advisable to keep to the instructions provided along with the detector drwg ref No 7038 Pic 16 INSTALLATION OF BARRI 88 WITH MAGNETIC LOOP DETECTOR OPTIONAL Code ref 2037L Preassembled loop 6 meters circumference Code ref 2042L Preassembled loop 12 meters circumference Code ref 2037L Preassembled loop 6 meters circumference Code ref 2042L Preassembled loop 12 meters circumference Loop detector L...

Page 10: ...te leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors officers and a copy of it must be handed over the en...

Page 11: ...11 BARRI 88 English Oil hydraulic road barrier with beam of 4 meters ...

Page 12: ... Absorbed current 1 8 A Absorbed power 330 W Capacitor 12 5 µF Motor rotation speed 1 350 rpm Intermittent service S3 Insulation class F ELECTRONIC PROGRAMMER Three relays One for safety 24 V 16 A Transformer 8 VA Capacitor 12 5 µF PERFORMANCE Frequency of use intensive Service cycle opening 5 s dwell 30 s closing 5 s dwell 30 s Complete cycle time 70 s Complete cycles pening dwell closing dwell N...