~ 500 mm
5 mm
Road level
4
SETTING THE ANCHORING BASE PLATE INTO THE GROUND FOUNDATION
The first operation is fixing the anchoring base plate on a flat level into a concrete foundation; it is advised that, during this phase,
one or two corrugated tubes, 30 mm of diameter, be laid in the foundation allowing for the electric cables to be driven through
(electric power supply to the installation, command and safety accessories), as illustrated in Pic. 4.
FITTING THE BEAM
E
n
g
li
sh
Pic. 4
Pic. 5
!
Important:
before cementing the anchoring base plate, drive the 2 bolts thoroughly out, to the end of the thread.
Important:
by means of a spirit level make sure the anchoring base plate be perfectly flat in both directions; it is
also recommended that it
be 5 mm higher
than the road finish level (Pic. 4).
~ 400 mm
245 mm
~ 400 mm
245 mm
65 mm
Two x M14 hook bolts
Ø 30
Ø 30
BARRI 88
0.0
1)
2)
3)
Oil-hydraulic road barrier with beam of 4 meters