fadini BARRI 88 Instruction Manual Download Page 2

2

BARRI 88

E

n

g

li

sh

Oil-hydraulic road barrier with beam of 4 meters

GENERAL WARNINGS FOR PEOPLE SAFETY

INTRODUCTION 

This operator is designed for the specific scope of applications 
as  indicated  in  this  manual,  it  includes  safety,  control  and 
signaling  accessories  as  minimum  required  and 

FADINI

 

equipment. 

  Any  applications  not  explicitly  included  in  this 

manual  may  cause  operation  problems  or  damages  to 
properties and people. 

 Meccanica Fadini snc is not liable for 

damages caused by the incorrect use of the equipment, or for 
applications not included in this manual or for malfunctioning 
resulting  from  the  use  of  materials  or  accessories  not 
recommended  by  the  manufacturer. 

  The  manufacturer 

reserves  the  right  to  make  changes  to  its  products  without 
prior notice. 

 All that is not explicitly indicated in this manual

is to be considered not allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 
of the access, its general condition and the structure. 

 Make 

sure  that  there  is  no  risk  of  impact,  crushing,  shearing, 
conveying,  cutting,  entangling  and  lifting  situations,  which 
may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with flammable substances. 

 Keep all 

the  accessories  able  to  turn  on  the  operator  (transmitters, 
proximity  readers,  key-switches,  etc)  out  of  the  reach  of  the 
children. 

  Transit  through  the  access  only  with  stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity  of  a  working  operator. 

  To  ensure  safety  in  the 

whole  movement  area  of  a  gate  it  is  advisable  to  install 
photocells,  sensitive  edges,  magnetic  loops  and  detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 
spots. 

  Before  cleaning  and  maintenance  operations, 

disconnect the appliance from the mains by switching off the 
master  switch. 

  If  removing  the  actuator,  do  not  cut  the 

electric  wires,  but  disconnect  them  from  the  terminal  box  by
loosening the screws inside the junction box. 

 Make sure that 

in the near proximity or inside the installation accessories there 
aren’t  any  electromagnetic  sources  of  disturbance,  such  that 
they  can  cover  or  affect  the  magnetic/electromagnetic 
detections  of  possible  loop  detectors  as  well  as  of  all  of  the 
electronic units that command and control the system.

INSTALLATION

All  installation  operations  must  be  performed  by  a  qualified 
technician,  in  observance  of  the  Machinery  Directive 
2006/42/CE  and  safety  regulations  EN  12453  -  EN  12445. 

Verify the presence of a thermal-magnetic 0,03 A - 230 V - 50 Hz 
circuit breaker where the main electric source of power of the 
installation  is  located. 

  Use  appropriate  objects  to  test  the 

correct  functionality  of  the  safety  accessories,  such  as 
photocells,  sensitive  edges,  etc. 

□ 

Carry  out  a  risk  analysis  by 

means of appropriate instruments measuring the crushing and 
impact  force  of  the  main  opening  and  closing  edge  in 
compliance with EN 12445. 

 Identify the appropriate solution

necessary to eliminate and reduce such risks.

 During the rotation of the beam there must not be obstacles 

or  points  of  contact  that  interfere  with  the  movement.

  In  case  where  the  gate  to  automate  is  equipped  with  a 

pedestrian entrance, it is appropriate to prepare the system in 
such a way to prohibit the operation of the engine when the 
pedestrian  entrance  is  used. 

  Apply  safety  nameplates  with 

CE  marking  on  the  gate  warning  about  the  presence  of  an 
automated  installation. 

  The  installer  must  inform  and 

instruct  the  end  user  about  the  proper  use  of  the  system  by 
releasing  him  a  technical  dossier,  including:  layout  and 
components  of  the  installation,  risk  analysis,  test  of  safety
accessories, test of impact forces and report of residual risks.

INFORMATION FOR END-USERS

The  end-user  is  required  to  read  carefully  and  to  receive 
information concerning only the operation of the installation 
so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with  the  installer/maintenance  technician  (on  -call). 

  Any 

maintenance operation must be done by qualified technicians. 

 Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE 
INSTALLATION

 

To achieve a long lasting performance of system in compliance 
with  the  safety  regulations,  it  is  necessary  that  proper 
maintenance  and  monitoring  of  the  entire  installation  be 
performed:  including  the  automation,  the  electronic 
equipment  and  the  cables  connected  to  these. 

 The  entire 

installation  must  be  carried  out  by  qualified  technical 
personnel, filling in the Maintenance Manual indicated in the 
Safety Regulation Book (to be requested or downloaded from 
the site www.fadini.net/supporto/downloads). 

 Operator: maintenance inspection at least every 6 months, 

while  for  the  electronic  equipment  and  safety  systems  an 
inspection  at  least  once  every  month  is  required. 

  The 

manufacturer,  Meccanica  Fadini  snc,  is  not  responsible  for 
non-observance  of  good  installation  practice  and  incorrect 
maintenance of the installation.

DISPOSAL OF MATERIALS

Dispose  properly  of  the  packaging  materials  such  as 
cardboard,  nylon,  polystyrene  etc.  through  specializing 
companies (after verification of the regulations in force at the 
place of installation in the field of waste disposal). Disposal of 
electrical  and  electronic  materials:  remove  and  dispose 
through specializing companies, as per Directive 2012/19/UE. 
Disposal  of  substances  hazardous  for  the  environment  is
prohibited

.

CE DECLARATION OF CONFORMITY of the manufacturer:

Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that: 

Barri 88

 complies 

with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic system”, along with original 
accessories and components as indicated by the manufacturing company. An automatic gate operator is, by law, a “machinery” 
and therefore the installer must fit the equipment with all of the applicable safety norms. The installer is also required to issue 
the installer’s Declaration of Conformity. The manufacturer is not liable for possible incorrect use of the product. The product 
complies with the following specific norms: analysis of the risks and subsequent action to cure them as per EN 12445 and EN 
12453,  Low  Voltage  Directive  2014/35/UE,  Electromagnetic  Compatibility  2014/30/UE.  In  order  to  certify  the  product,  the
manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT NORMS.

Meccanica Fadini s.n.c.

Director in charge

Summary of Contents for BARRI 88

Page 1: ... 12 GB Instructions manual pages Oil hydraulic road barrier for 4 meters gateways Left and right handed versions Folding or fixed pedestal options Adjustable slowdown in opening and closing option with articulated arm thegateopener ...

Page 2: ...ate is equipped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gate warning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical do...

Page 3: ...ulic actuator 4 Main assembly motor pump actuator 5 Pressure control valves 6 Balance spring 7 Anchoring base plate with hook bolts 8 Emergency release 9 Elpro 88 control board 10 Control board support arm 11 Beam limit switch assembly with adjustment screws 12 80x30 L 4 m beam 13 Folding pedestal 14 Fixed pedestal optional Barri 88 Left Sx Barri 88 Right Dx BARRI 88 Entry side Entry side Oil hydr...

Page 4: ... power supply to the installation command and safety accessories as illustrated in Pic 4 FITTING THE BEAM English Pic 4 Pic 5 Important before cementing the anchoring base plate drive the 2 bolts thoroughly out to the end of the thread Important by means of a spirit level make sure the anchoring base plate be perfectly flat in both directions it is also recommended that it be 5 mm higher than the r...

Page 5: ... THE POST SUPPORTING THE PHOTOCELL FIXED PEDESTAL INSTALLATION 5 English Pic 6 Pic 7 TRIFO 11 BARRI 88 Ø 30 Ø 30 Ø 30 Junction pit Post mounted with TRIFO 11 photocell Oil hydraulic road barrier with beam of 4 meters ...

Page 6: ...technical data section in this manual to be filled in in compliance with the EN 12445 and EN 12453 regulations For power supply electric motor and flasher 1 mm square section cables are to be used up to 50 meters of distance For longer distances suitable cables are to be used following the standards of a good technical installation Electric cables having wires of 0 5 mm square section are to be used...

Page 7: ...crews Pic 10 SLOWING DOWN AT END OF MOVEMENTS BARRI 88 BARRI 88 LEFT BARRI 88 RIGHT Pic 10 UNSCREW ADJUSTMENT LOCK TIGHTEN ADJUSTMEN LOCK LIMIT SWITCH ADJUSTMENT HORIZONTAL BEAM LIMIT SWITCH ADJUSTMENT HORIZONTAL BEAM LIMIT SWITCH ADJUSTMENT VERTICAL BEAM LIMIT SWITCH ADJUSTMENT VERTICAL BEAM 1st OPERATION 2nd OPERATION 3rd OPERATION Pic 11 SLOWDOWN SETTING OPENING BARRI 88 RIGHT SLOWDOWN SETTING ...

Page 8: ... 88 LEFT BARRI 88 RIGHT green screw POWER CONTROL OPENING red screw POWER CONTROL OPENING red screw POWER CONTROL CLOSING green screw POWER CONTROL CLOSING max 1 2 turns less power more power less power more power Pic 14 GREASE PERIODICALLY ONCE A YEAR AT LEAST Oil hydraulic road barrier with beam of 4 meters ...

Page 9: ...s advisable to keep to the instructions provided along with the detector drwg ref No 7038 Pic 16 INSTALLATION OF BARRI 88 WITH MAGNETIC LOOP DETECTOR OPTIONAL Code ref 2037L Preassembled loop 6 meters circumference Code ref 2042L Preassembled loop 12 meters circumference Code ref 2037L Preassembled loop 6 meters circumference Code ref 2042L Preassembled loop 12 meters circumference Loop detector L...

Page 10: ...te leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors officers and a copy of it must be handed over the en...

Page 11: ...11 BARRI 88 English Oil hydraulic road barrier with beam of 4 meters ...

Page 12: ... Absorbed current 1 8 A Absorbed power 330 W Capacitor 12 5 µF Motor rotation speed 1 350 rpm Intermittent service S3 Insulation class F ELECTRONIC PROGRAMMER Three relays One for safety 24 V 16 A Transformer 8 VA Capacitor 12 5 µF PERFORMANCE Frequency of use intensive Service cycle opening 5 s dwell 30 s closing 5 s dwell 30 s Complete cycle time 70 s Complete cycles pening dwell closing dwell N...

Reviews: