General layout; it is the installer’s care to provide and properly lay the tubes
in the most suitable way for the cables to be led through.
Important:
the entire installation must be properly grounded.
The voltage cut-off switch is factory-fitted on demand on to the control
box support arm and touches the door. On opening the door, the 230 V -
50 Hz power supply is automatically disconnected, whole unit safe.
All ground wires to be properly connected to the dedicated terminals.
6
MAIN COMPONENTS FOR THE ELECTRICAL INSTALLATION
IMPORTANT:
cabling and electrical connections are to be carried out to the rules of the art, in compliance with the general standards
of a good technical installation, in full respect of the safety norms in force (Machinery Directive 2006/42/CE) by qualified technicians.
An accurate analysis of the hazards involved is to be formulated, proper actions to cure are to be taken and the technical data
section in this manual to be filled in, in compliance with the EN 12445 and EN 12453 regulations.
For power supply, electric motor and flasher 1 mm² square section cables are to be used up to 50 meters of distance. For longer
distances, suitable cables are to be used following the standards of a good technical installation.
Electric cables having wires of 0,5 mm² square section are to be used for all the accessories external to the electric board.
INSTALLATION OF THE VOLTAGE CUT-OFF SWITCH (OPTIONAL)
En
g
lis
h
Pic. 8
Pic. 9
1
2
4
3
5
6
8
7
n° 2x0,5
n° 3x1
1. 230 V - 50 Hz magneto-thermal 0,03 A circuit breaker
(not provided with the equipment). Beyond 100 m cable section to be 2,5 mm²
2. Miri 4 flasher with Birio A8 aerial
3. Trifo 11 photocell receiver
4. Barri 88 oil-hydraulic barrier with Elpro 88 controller
and Vix 53/2 R plug-in radio receiver
5. Fixed pedestal with fork end
6. Trifo 11 photocell projector
7. Post with Trifo 11 mounted on it
8. Vix 53/4 TR transmitter
BARRI 88
OPTIONAL
16 17
230 V
50 Hz
ELPRO 88
VOLTAGE
CUT-OFF
(OPTIONAL)
230 V
50 Hz
Oil-hydraulic road barrier with beam of 4 meters