VENTING   REQUIREMENTS

Determine which venting method is best for your application.  

Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should 

be kept to a minimum to provide efficient performance.  The 

size of the ductwork should be uniform.  Do not install two 

elbows together.  Use duct tape to seal all joints in the ductwork 

system.  Use caulking to seal exterior wall or floor opening 

around the cap.

Flexible ductwork is not recommended.  Flexible ductwork 

creates  back  pressure  and  air  turbulence  that  greatly 

reduces performance.

Make sure there is proper clearance within the wall or floor 

for exhaust duct before making cutouts.  Do not cut a joist or 

stud unless absolutely necessary.  If a joist or stud must be 

cut, then a supporting frame must be constructed

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 

TO PAGE 4.

WARNING - To Reduce The Risk Of Fire, Use Only Metal 

Ductwork.

• Venting system MUST terminate outside the 

home.

• DO NOT terminate the ductwork in an attic or 

other enclosed space.

• DO NOT use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• DO NOT obstruct the flow of combustion and 

ventilation air.

• Failure to follow venting requirements may result 

in a  fire.

This  appliance  should  be  connected  directly  to  the  fused 

disconnect (or circuit breaker) through flexible, armored or 

nonmetallic sheathed copper cable.  Allow some slack in the 

cable so the appliance can be moved if servicing is ever nec

-

essary.  A UL Listed, 1/2" conduit connector must be provided 

at each end of the power supply cable (at the appliance and 

at the junction box).

When making the electrical connection, cut a 1  1/4" hole in the 

wall.  A hole cut through wood must be sanded until smooth.  

A hole through metal must have a grommet. 

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 

SHOCK, do not use this fan with any solid-state speed 

control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI

-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:  Use this unit only in the manner intended 

by the manufacturer.  If you have any questions, contact 

the manufacturer.

Before servicing or cleaning unit, switch power off at 

service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally.  

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a 

tag, to the service panel.

CAUTION:  For  General  Ventilating  Use  Only.    Do  Not 

Use To Exhaust Hazardous  or  Explosive Materials and 

Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI

-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING: Installation Work And Electrical Wiring Must 

Be Done By Qualified Person(s) In Accordance With All 

Applicable Codes And Standards, Including Fire-Rated 

Construction.  

Sufficient  air  is  needed  for  proper  combustion  and 

exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting.  Follow the 

heating equipment manufacturer's guideline and safety 

standards such as those published by the National Fire 

Protection Association (NFPA), and the American Society 

for Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not dam

-

age electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.

   WARNING

• Electrical ground is required on this rangehood.

• If cold water pipe is interrupted by plastic, 

nonmetallic gaskets or other materials, DO NOT 

use for grounding.

• DO NOT ground to a gas pipe.

• DO NOT have a fuse in the neutral or grounding 

circuit.  A fuse in the neutral or grounding circuit 

could result in electrical shock.

• Check with a qualified electrician if you are in doubt 

as to whether the rangehood is properly grounded. 

• Failure to follow electrical requirements may result 

in a fire.   

   WARNING

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a 

separate 15 amp fused circuit.  A time-delay fuse or circuit 

breaker is recommended.  The fuse must be sized per local 

codes in accordance with the electrical rating of this unit as 

specified  on  the  serial/rating  plate  located  inside  the  unit 

near the field wiring compartment.  THIS UNIT MUST BE 

CONNECTED  WITH  COPPER  WIRE  ONLY.    Wire  sizes 

must conform to the requirements of the National Electrical 

Code, ANSI/NFPA 70 - latest edition, and all local codes and 

ordinances.  Wire size and connections must conform with the 

rating of the appliance.  Copies of the standard listed above 

may be obtained from: 

 

National Fire Protection Association

 

Batterymarch Park

 

Quincy, Massachusetts  02269

For residential use only.

!

!

Cold Weather installations

An  additional  back  draft  damper  should  be  installed  to  minimize 

backward cold air flow and a nonmetallic thermal break should be 

installed to minimize conduction of outside temperatures as part of 

the vent system. The damper should be on the cold air side of the 

thermal break. The break should be as close as possible to where 

the vent system enters the heated portion of the house.

CAUTION

 - To reduce risk of fire and to properly exhaust 

air, be sure to duct air outside – Do not vent exhaust air into 

spaces within walls or ceilings or into attics, crawl spaces, or 

garages.

Summary of Contents for ORIZZONTE

Page 1: ...ndards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See E...

Page 2: ...TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING InstallationWorkAndElectricalWiringMust Be Done By Qualified Person s In Accordance With All Applicable Codes A...

Page 3: ...die et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Air Climatis ainsi que les codes municipaux En per ant un mur veillez ne pas perforer un autre fil lectrique Une ventilateur...

Page 4: ...aber Saw or Jig Saw Drill 1 1 4 Wood Drill Bit Scissors Pliers Phillips Screwdriver Flat Blade Screwdriver Wire Stripper or Utility Knife Metal Snips Measuring Tape or Ruler Level Pencil Caulking Gun...

Page 5: ...ignedtomeetvaryingceilingheights The chimneyscanbeadjustedforceilingsbetween 7 10 3 16 8 9 3 16 Forshorterceilings havethechimneycover s cut at a sheet metal shop For higher ceiling installations the...

Page 6: ...designedtomeetvaryingceilingheights The chimneyscanbeadjustedforceilingsbetween 8 3 3 16 8 9 15 16 Forshorterceilings havethechimneycover s cut at a sheet metal shop For higher ceiling installations t...

Page 7: ...r side as indicated in FIGURE 4 and install the MOUNTING SCREWS into the wall leaving about 1 4 gap between the wall and the head of the screw 8 For ducted installations determine and make all necessa...

Page 8: ...grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire con nector Attach the Black lead of the power supply...

Page 9: ...not operate disconnect the power supply and check that the wiring connec tions have been made properly FIGURE 12 USE AND CARE INFORMATION This rangehood system is designed to remove smoke cooking vapo...

Page 10: ...ion is visible only when the motor is off By pressing this key the 30 minute delay shutdown mode is activated which is used to eliminate any residual odor in the kitchen for 30 minutes After 30 minute...

Page 11: ...lace the metal grease filters and close the ducting panels Charcoal Filter Alarm Activation The filter alarm has to be activated in order to use with ductless installations which use the charcoal filt...

Page 12: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Page 13: ...re de ferrures FIGURE 1 D E F 1 n cessaire de documentation PI CES N CESSAIRES POUR L INSTALLATION 2 connecteurs de conduit C ble d alimentation 1 capuchon de mur ou de toit Conduit en m tal ACCESSOIR...

Page 14: ...deplafonds Leshotteschemin e peuvent tre ajust es des plafonds entre 7 10 3 16 8 9 3 16 de hauteur Pour les plafonds plus bas le couvercle de la chemin e doit tre coup dans un atelier de coupedem tal...

Page 15: ...afonds Leshotteschemin e peuvent tre ajust es des plafonds entre 8 3 3 16 8 9 15 16 de hauteur Pour les plafonds plus bas le couvercle de la chemin e doit tre coup dans un atelier de coupedem tal Pour...

Page 16: ...FIGURE 4 et installer les VIS DE FIXATIONS au mur Ne pas installer compl tement les VIS DE FIXATIONS au mur en laisser un espace de 1 4 po entre le mur et la t te de la vis 8 Pour les installations a...

Page 17: ...t jaune et vert sous la vis de mise la terre verte Replacer le couvercle du compartiment de c blage 2 Installer la CHEMIN E SUP RIEURE C de la FIGURE 8 Elargir l g rement les deux bords lat raux de la...

Page 18: ...pas grill Si l appareil ne fonctionne toujours pas d brancher l alimentation et v rifier si les connexions ont t effectu es correctement UTILISATION ET ENTRETIEN Cette hotte est con ue pour enlever la...

Page 19: ...er en pressant ce bouton pendant 3 secondes L affichage n est visible que lorsque le moteur est teint En pressant ce bouton le mode d lai de fermeture de 30 minutes est activ lequel est utilis pour li...

Page 20: ...par un nouveau Replacer ensuite le filtre graisse et fermer les panneaux du conduit Activation de l Alarme du Filtre au Charbon L alarme de filtre charbon doit tre activ e de fa on tre utilis e avec l...

Page 21: ...r les fusibles de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de...

Reviews: