Faber ORIZZONTE Installation Instructions; Use And Care Information Download Page 10

Version 07/11 - Page 10

USE AND CARE CONTINUED - CONTROL PANEL

FIGURE 14

Key

A

B

C

D

E

F

G

H

Function

Switches  the  blower  motor  on  and  off  at  the  last  selected 

speed 

Decreases the vent speed.

Increases the vent speed.

By pressing this key the 

intensive boost function

 is activated 

from any previously selected speed. The intensive boost can 

be activated even when the motor is OFF. After ten minutes of 

intensive power, the hood switches back to the last selected 

speed. This function is recommended for cooking conditions 

where vapors and odors need to be eliminated immediately 

and quickly. 

By pressing this key the 

24 hr - function 

is set which turns 

the hood on at 60 CFM for 10 minutes every hour with a noise 

level of just .5 sones. This setting can operate all day and 

night to 

refresh and clean your home

.  After  10 minutes 

every hour, the motor switches off automatically. Press the 

button again to turn off the 24 hour function.

When the grease or charcoal filter saturation alarm is triggered  

it is possible to reset the alarm by pressing this key for  3 seconds. 

The indication is visible only when the motor is off.

By pressing this key the 

30 minute 

delay shutdown

 mode is 

activated which is used to eliminate any residual odor in the 

kitchen for 30 minutes. After 30 minutes the hood turns off. It 

can be turned on at any speed, and it is turned off by pressing 

the key again or by switching off the motor.

Turns light on and off .

Turns the night light on and off.

Related LED Display Symbol

The  current  speed  is  shown  when  the  hood  is 

turned on.

HI

  appears. The red dot on the right side flashes 

once per second.

Indicates the 

24 hr - function

. The red dot on 

the right side flashes and the motor is on.

FF

 

Indicates that the metal grease filter    

 

saturation  alarm  has  been  triggered,  and  

 

the  filters  need  to  be  washed.  The  alarm  

 

is  triggered  after  100  working  hours. 

See  

 

the next page for instructions on    

 

resetting the alarm

 

EF

 

Indicates that the charcoal filter 

 

saturation  alarm  has  been  triggered,  and  

 

the filter has to be replaced;  The  

 

 

charcoal filter is triggered after 200 

 

working  hours. 

See  the  next  page  for  

 

instructions on resetting the alarm

 

 

Indicates both the selected speed of the hood and 

the time left before the hood shutdown. The red dot 

on the right side flashes alternately displaying the 

speed and shutdown time.

Summary of Contents for ORIZZONTE

Page 1: ...ndards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See E...

Page 2: ...TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING InstallationWorkAndElectricalWiringMust Be Done By Qualified Person s In Accordance With All Applicable Codes A...

Page 3: ...die et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Air Climatis ainsi que les codes municipaux En per ant un mur veillez ne pas perforer un autre fil lectrique Une ventilateur...

Page 4: ...aber Saw or Jig Saw Drill 1 1 4 Wood Drill Bit Scissors Pliers Phillips Screwdriver Flat Blade Screwdriver Wire Stripper or Utility Knife Metal Snips Measuring Tape or Ruler Level Pencil Caulking Gun...

Page 5: ...ignedtomeetvaryingceilingheights The chimneyscanbeadjustedforceilingsbetween 7 10 3 16 8 9 3 16 Forshorterceilings havethechimneycover s cut at a sheet metal shop For higher ceiling installations the...

Page 6: ...designedtomeetvaryingceilingheights The chimneyscanbeadjustedforceilingsbetween 8 3 3 16 8 9 15 16 Forshorterceilings havethechimneycover s cut at a sheet metal shop For higher ceiling installations t...

Page 7: ...r side as indicated in FIGURE 4 and install the MOUNTING SCREWS into the wall leaving about 1 4 gap between the wall and the head of the screw 8 For ducted installations determine and make all necessa...

Page 8: ...grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire con nector Attach the Black lead of the power supply...

Page 9: ...not operate disconnect the power supply and check that the wiring connec tions have been made properly FIGURE 12 USE AND CARE INFORMATION This rangehood system is designed to remove smoke cooking vapo...

Page 10: ...ion is visible only when the motor is off By pressing this key the 30 minute delay shutdown mode is activated which is used to eliminate any residual odor in the kitchen for 30 minutes After 30 minute...

Page 11: ...lace the metal grease filters and close the ducting panels Charcoal Filter Alarm Activation The filter alarm has to be activated in order to use with ductless installations which use the charcoal filt...

Page 12: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Page 13: ...re de ferrures FIGURE 1 D E F 1 n cessaire de documentation PI CES N CESSAIRES POUR L INSTALLATION 2 connecteurs de conduit C ble d alimentation 1 capuchon de mur ou de toit Conduit en m tal ACCESSOIR...

Page 14: ...deplafonds Leshotteschemin e peuvent tre ajust es des plafonds entre 7 10 3 16 8 9 3 16 de hauteur Pour les plafonds plus bas le couvercle de la chemin e doit tre coup dans un atelier de coupedem tal...

Page 15: ...afonds Leshotteschemin e peuvent tre ajust es des plafonds entre 8 3 3 16 8 9 15 16 de hauteur Pour les plafonds plus bas le couvercle de la chemin e doit tre coup dans un atelier de coupedem tal Pour...

Page 16: ...FIGURE 4 et installer les VIS DE FIXATIONS au mur Ne pas installer compl tement les VIS DE FIXATIONS au mur en laisser un espace de 1 4 po entre le mur et la t te de la vis 8 Pour les installations a...

Page 17: ...t jaune et vert sous la vis de mise la terre verte Replacer le couvercle du compartiment de c blage 2 Installer la CHEMIN E SUP RIEURE C de la FIGURE 8 Elargir l g rement les deux bords lat raux de la...

Page 18: ...pas grill Si l appareil ne fonctionne toujours pas d brancher l alimentation et v rifier si les connexions ont t effectu es correctement UTILISATION ET ENTRETIEN Cette hotte est con ue pour enlever la...

Page 19: ...er en pressant ce bouton pendant 3 secondes L affichage n est visible que lorsque le moteur est teint En pressant ce bouton le mode d lai de fermeture de 30 minutes est activ lequel est utilis pour li...

Page 20: ...par un nouveau Replacer ensuite le filtre graisse et fermer les panneaux du conduit Activation de l Alarme du Filtre au Charbon L alarme de filtre charbon doit tre activ e de fa on tre utilis e avec l...

Page 21: ...r les fusibles de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de...