Glass Removal
SAFETY PRECAUTIONS
The ceramic glass is very fragile and should be handled with care.
1. Loosen the coupling nuts on the bottom front
glass bracket using a small wrench or socket set.
Do not completely remove.
2. Remove coupling nuts from top front glass
bracket using a small wrench or socket set.
Remove all coupling nuts leaving the middle
one until last.
3. Carefully taking a sharp blade and cut silicone sealant front edges on exposed glass edges.
4. Attach glass suction cups to the glass. Remove the last coupling nut and hold glass with suction cup and remove
bottom bracket. Slowly swing glass out from bottom and remove glass.
5.
!
set before the glass can be removed.