8
DL 1
Power supply
ON
Power on
OFF
Power off
DL 2
Transmission channel and charge of the TX battery
ON
TX Battery OK
Slow
flashing
Indication of transmission channel
Rapid
flashing
TX Battery almost discharged
OFF
TX battery flat or
Photocell engaged
DL 3
Alignment
ON
Alignment OK
Slow
flashing
Alignment not correct
OFF
Non-alignment or
Photocell engaged
CHECKING THE INDICATOR LEDS FOR THE RX
The states and significance of the LEDs on the Receiver are
shown below; refer to figure 8 to find their position.
CHECKING THE INDICATOR LEDs FOR THE TX
The states and significance of the LEDs on the Transmitter
are shown below; refer to figure 9 to find their position.
DL 1
Power supply
ON
Mains power supply on
OFF
Mains power supply off, battery operation
DL 2
Transmission channel
OFF
Normal Operation
Slow
flashing
Display of the transmission channel
Complete the installation by closure of the photocells
just installed with the appropriate four-screw closing plug,
being careful to position the rubber separator (indicated
in figs. 2, 3 ref.
햲
) so as to ensure the correct degree of
IP insulation
6. TROUBLESHOOTING
Help with the identification and resolution of particular conditions regarding operation of the photocells is given
below.
For a complete list of the error/breakdown situations, refer to the instructions for the control unit used to move the
application.
CONDITION
CAUSE/PROBLEM
SUGGESTION
The gate does not move. The
DL2 and DL3 Receiver LEDs are
off.
- Non-alignment
- The Transmitter is not receiving
power
- Incorrect choice of transmission
channel.
- Check the selection of the transmission
channel.
- Check the power supply to the pair of
photocells.
- Check the alignment of the pair.
The DL2 Receiver LED flashes.
Incorrect power supply to the
Transmitter.
- Replace the battery inside the Transmitter.
- If the Transmitter is mains powered, check
the voltage.
The DL3 Receiver LED flashes
The photocells are not correctly
aligned.
- Adjust the alignment of the photocells.
Whilst the channel set is being displayed, the
pair of photocells is inactive and its contact is
therefore OPEN. Wait for the end of the display
to operate the automated system.