3. J275 2K HA

3.1  INTENDED USE

The J275 2K HA, is an automatic hydraulic bollard designed for pe-
rimeter protection applications.
Installations using the J275 2K HA must be used for vehicular traffic.
To lower the bollard manually, follow the instructions in 

§ 4.6

.

 

!

Any other use that is not expressly specified in these instructions is 
prohibited and could affect the integrity of the product and/or represent 
a source of danger.

3.2  LIMITATIONS OF USE

Comply with the limitations on frequency of use listed in the techni-
cal data section.
The presence of snow, ice and strong wind, even occasional, could 
affect the operation of the automation, the integrity of the com-
ponents and become a potential source of danger (see section 

§

 

Emergency use). 
 The  J275 2K HA must be connected to a FAAC JE275 electronic board.
Implementing the automation requires the installation of the neces-
sary safety devices, identified by the installer through an appropriate 
risk assessment of the installation site.  The installation must be visible 
during the day and at night.  If it is not, appropriate solutions must be 
provided in order to make the fixed and moving parts visible .

3.3 UNAUTHORISED USE

 

-

Uses other than the intended use are prohibited.

 

-

It is prohibited to install the automation outside of the limits 
specified in the Technical Data and Installation Requirements 
sections.

 

-

It is prohibited to use the J275 2K HA in a configuration other 
than the one intended by the manufacturer.

 

-

No component part of the product may be modified.

 

-

It is prohibited to install the automation on escape routes.

 

-

 It is prohibited to install the automation in environments in which 
there is a risk of explosion and/or fire: the presence of flamma-
ble gases or fumes is a serious safety hazard (the product is not 
94/9/EC ATEX certified).

 

-

It is prohibited to power the system with energy sources other 
than those specified.

 

-

It is prohibited to integrate commercial systems and/or equip-
ment other than those specified, or use them for purposes not 
intended and authorised by their respective manufacturers.

 

-

   It is prohibited to use and/or install accessories that have not 
been specifically approved by FAAC S.p.A.

 

-

It is prohibited to use the automation before performing com-
missioning.

 

-

It is prohibited to use the automation in the presence of faults 
which could compromise safety.

 

-

It is prohibited to use the automation with the fixed and/or 
mobile guards removed or altered.

 

-

Do not use the automation unless the area of operation is free 
of persons, animals or objects.

 

-

Do not enter/remain in the area of operation of the automation 
while it is moving.

 

-

Do not try to prevent the movement of the automation.

 

-

Do not climb or hold on to the cylinder or lift yourself up on it.  

 

-

 Do not allow children to approach or play in the area of operation 
of the automation.

 

-

Do not allow the control devices to be used by anyone who is 
not specifically authorised and trained to do so.

 

-

Do not allow the control devices to be used by children or persons 
with mental and physical deficiencies unless they are supervised 
by an adult who is responsible for their safety.

 

 

 

3.4  EMERGENCY USE

In the event of a malfunction, emergency or failure, disconnect the 
power supply to the automation.  Place the automation out of 
service until it has been reset/repaired.
In the case of a breakdown, the automation system must be reset/
repaired exclusively by the INSTALLER/MAINTENANCE TECHNICIAN.

3.5 PRODUCT IDENTIFICATION

The product can be identified by the plate (see 

1

).

Sale code
Product name
IDENTIFICATION NUMBER 
Month/year of prod progressive 
number for the month of production
Example:   

0117 

0001

produced in January 2017  S/N 1 

Summary of Contents for J275 2K HA

Page 1: ...J275 2K HA...

Page 2: ...s cit s sont la propri t de leurs fabricants respectifs Les clients peuvent faire des copies pour leur usage exclusif Ce manuel a t publi en 2017 Copyright FAAC S p A ab dem 2017 Alle Rechte vorbehalt...

Page 3: ...ols used 4 2 SAFETY RECOMMENDATIONS 5 2 1 Installer safety 5 3 J275 2K HA 6 3 1 Intended use 6 3 2 Limitations of use 6 3 3 Unauthorised use 6 3 4 Emergency use 6 3 5 Product identification 6 3 6 Tech...

Page 4: ...alysis and drafting the instruc tions for use and maintenance of the machine It should be clearly understoodthatFAACS p A acceptsnoliabilityforthereliabilityand or completeness of the above instructio...

Page 5: ...C The installer is responsible for the installation testing of the automa tion and for completing the Register of the system The installer must prove or declare to possess technical and profes sional...

Page 6: ...resence of flamma ble gases or fumes is a serious safety hazard the product is not 94 9 EC ATEX certified It is prohibited to power the system with energy sources other than those specified It is proh...

Page 7: ...dule with cable routing hole x1 3 Cable gland 4 Side module x7 5 Base with water drainage holes Pit 3 7 COMPONENT IDENTIFICATION 3 6 TECHNICAL CHARACTERISTICS The cylinder is moved by an internal hydr...

Page 8: ...15 C 55 C Ambient operating temperature with optional heater 25 C 55 C Type of use Intensive Bollard weight 160 kg Pit weight 60 kg Oil quantity 1 5 l Oil type FAAC HP OIL Protection rating IP56 Hydr...

Page 9: ...tres of water into the hole making sure that it drains in less than 30 minutes If it takes longer drain rainwater by installing a 60mm pipe connected to the drainage system or a pit The pitmustbefitte...

Page 10: ...200 200 6 6 22 Translation of the original instructions ENGLISH 4 3 MAKING THE CAGE The foundation cage is not supplied by FAAC and has to be made on site 1 7 Make and assemble the cage according to...

Page 11: ...the final road surface 4 10 Install a flexible sheath ID 45 mm from the cable gland to the control board 1 L The maximum distance between the bollard and the board is 50 m 5 Install the conduits requ...

Page 12: ...hroughthecable gland provided 2 4 Connect the conductors to the external junction box and the control board following the instructions in section 5 1 5 Check that the bollard operates correctly accord...

Page 13: ...ten the cover to the frame using the eight M6x10 screws L To reposition or lift the cover prise one of the two slots upwards using a screwdriver 4 6 MANUAL OPERATION Beforecarryingoutthereleaseprocedu...

Page 14: ...Replace the plugs 1 4 Lift the head in order to access the release device 5 Turn the release device anticlockwise using the key provided RESTORING AUTOMATIC OPERATION 1 21 Turn the release device clo...

Page 15: ...utomation must be fitted with a 0 03 A differential switch Install a circuit breaker and a differential switch upstream of each control board The metal parts of the structure must be earthed Check tha...

Page 16: ...bollard J275 2K HA by performing the following operation 1 Accesslevel1programmingbyholdingdowntheFbuttononthe board 26 The letters dF will appear on the display 2 Release the F button and with the b...

Page 17: ...COM COM LAMP FAN J1 J2 M4 M5 M6 1 2 3 4 5 6 J5 J3 1 2 3 1 2 3 J5 J3 4 5 6 4 5 6 1 dF 05 2 o 1 1 1 P1 no o2 12 P2 no 3 b6 Y F F F F F F 10 s 1 dF 05 LO C 2 03 Y b6 Y 3 LO Cu 4 o 3 1 5 P3 no F F F F F...

Page 18: ...reachesthehighposition and reverses immediately Make sure that the limit switches are wired correctly 25 Makesurethattheupperlimitswitchisinthe correct position 2 7 The bollard does not raise Make sur...

Page 19: ...pleting mainte nance Before starting activities wait for the components subject to heating to cool down Do not modify the original components in any way FAAC S p A disclaims any liability for damage c...

Page 20: ...heck the mechanical stops fastening and solidity 12 Makesurethatthecylinderiscleanandifnecessarytouchupthepaintwork Checkthattheautomationsystemoperatescorrectly followingtheset logic when using the v...

Page 21: ...lange together with the seal provided Insert the cable in to the cable gland 2 and connect it to connector 3 inside the junction box according to the diagram shown in the figure Pink Blue Blue Violet...

Page 22: ...istribution flange 4 Screw the solenoid valve onto the distribution flange 5 Install the control coil onto the solenoid valve 6 Remove the plug from the cable gland 41 1 insert the cable andconnectitt...

Page 23: ...of the relative control board master or slave as indicated in the following diagram Master JE275 board Slave JE275 board 7 3 COVER Use the cover to make the pit of the bollard which has not yet been...

Page 24: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com J275 2K HA 24 532208 Rev A...