FAAC GENIUS Sprint 382 Manual Download Page 4

Fig. 1

Fig. 2

SPRINT  382  -  SPRINT  383 

00058I0112        -  Rev.6

FCA

FCC

OPEN

A

OPEN

B

FSW 

CL

FSW 

OP

EDGE 

SAFE

STOP

C

J4

Tr

ansla

tion of the original instruc

tions

ENGLISH

CONTROL BOARD SPRINT 382 - SPRINT 383

1. WARNINGS

 Before attempting any work on the control board (connections, mainte-

nance), always turn off power.

  

Install, upstream of the system, a differential thermal breaker with ade-
quate tripping threshold.

 

Connect the earth cable to the appropriate terminal on the J7 connector 
of the equipment (see 

fi

 g.2).

 

Always separate power cables from control and safety cables (push-
button, receiver, photocells, etc.). To avoid any electric noise, use separate 
sheaths or a shielded cable (with earthed shield).

2. TECHNICAL SPECIFICATIONS

Sprint 382

Sprint 383

Power supply

230 V~ ( +6%  -10%) - 50 Hz

115 V~ - 60 Hz

Absorbed power

10 W

Motor max. load

1000 W

Accessories max. load

0,5 A

Operating ambient tempe-
rature

-20 °C +55 °C

Protection fuses

2 (see 

fi

 g. 1)

Function logics

Automatic / “Stepped” automatic / Semi-automatic 

/ Safety devices / Semi-automatic B / Dead-man C 

/ “Stepped” semi-automatic / Mixed Log. B+C

Work time

Programmable (from 0 to 4 min.)

Pause time

Programmable (from 0 to 4 min.)

Thrust force

Adjustable over 50 levels

Terminal board inputs

Open / Pàartial opening / Safety devices at opng. 

/ Safety devices at clsng. / Stop / Edge / Power 

Earth

On-connector inputs

Opening and closing limit-switches / Encoder

Terminal board outputs

Flashing lamp - Motor - 24 Vdc accessories power 

supply - 24 Vdc indicator-light / Timed output. - 

Fail safe

Rapid connector

5-pin card connection for receivers

Programming

3 keys (+, -, F) and display, “basic” or “advanced” 

mode

Basic mode programmable 
functions

Function logic - Pause time - Thrust Force - Gate 

direction

Advanced mode programma-
ble functions

Torque at initial thrust - Braking - Fail safe - Pre-

fl

 ashing - Indicator-light/Timed output -

 Opening and closing safety devices logic -

 Encoder - Decelerations - Partial opening time - 

Work time - Assistance request - Cycle counter

DL

SIGNALLING AND PROGRAMMING DISPLAY

Led

INPUTS STATUS CONTROL LED

J1

LOW VOLTAGE TERMINAL BOARD

J2

CONNECTOR FOR RECEIVER

J3

ENCODER CONNECTOR

J4

CAPACITOR CONNECTOR

J5

LIMIT -SWITCH CONNECTOR

J6

MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD

J7

POWER SUPPLY TERMINAL BOARD

F1

MOTORS AND TRANSF. PRIMARY FUSE 
(Sprint 382 F 5A - Sprint 383 10A)

F2

LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)

F

“F” PROGRAMMING PUSH-BUTTON 

-

“–” PROGRAMMING PUSH-BUTTON

+

“+” PROGRAMMING PUSH-BUTTON

4. ELECTRIC CONNECTIONS

3. LAYOUT AND COMPONENTS

*

 Only if don’t use J4 connector

Grey/Blue

Black

Brown

230 V~ (Sprint 382)

 or

115 V~ (Sprint 383)

230 V~ (Sprint 382)

 or

115 V~ (Sprint 383)

MAX 60W

Summary of Contents for GENIUS Sprint 382

Page 1: ...print 382 Sprint 383 Translation of the original instructions Traductiondelanoticeoriginale bersetzung der Original Anleitung Traducci ndelmanualoriginal Vertalingvandeoorspronkelijkegebruiksaanwijzin...

Page 2: ...crushing safety device consisting of a torque control Nevertheless its tripping threshold must be checked as specified in the Standards indicated at point 10 16 The safety devices EN 12978 standard pr...

Page 3: ...INPUTS CHECK page 7 7 AUTOMATED SYSTEM TEST page 7 EU DECLARATION OF CONFORMITY The Manufacturer Company name FAAC S p A Soc Unipersonale Address Via Calari 10 40069 Zola Predosa BOLOGNA ITALY hereby...

Page 4: ...rd inputs Open P artial opening Safety devices at opng Safety devices at clsng Stop Edge Power supply Earth On connector inputs Opening and closing limit switches Encoder Terminal board outputs Flashi...

Page 5: ...against the risk of impact Opening closing safety devices they operate during the gate opening and closing movements and therefore they are suitable for protecting the opening and closing areas again...

Page 6: ...PEN A Total Opening command terminal 1 any pulse generator push button detector etc which by closing a contact commands total opening and or closing of the gate leaf To install several total opening p...

Page 7: ...essories terminals 7 and 8 24 Vdc Positive for power supply to accessories terminals 9 and 10 Accessories max load is 500 mA To calculate absorption values refer to the instructions for individual acc...

Page 8: ...e sequence of functions accessible in ADVANCED PROGRAMMING ADVANCED PROGRAMMING F Display Function Default b0 MAXIMUM TORQUE AT INITIAL THRUST The motor operate at maximum torque ignoring the torque s...

Page 9: ...ng to the performed deceleration spaces 2 0 ADVANCED PROGRAMMING F Display Function Default AS ASSISTANCE REQUEST combined with next function If activated at the end of countdown settable with the nex...

Page 10: ...No effect OPEN disabled No effect No effect OPEN disabled OPEN on PAUSE Stops operation Stops operation No effect Reloads pause time OPEN disabled No effect OPEN disabled ON CLOSING Re opens the leaf...

Page 11: ...o effect OPEN disabled No effect No effect OPEN disabled OPEN Re closes the leaf immediately Stops operation No effect No effect OPEN disabled ON CLOSING Stops operation No effect saves OPEN see parag...

Page 12: ...effect OPEN A B disabled Tab 3 h LOGIC BC OPENING PULSES CLOSING COMMANDS ALWAYS PRESSED PULSES GATE STATUS OPEN A opening OPEN B closing STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP CLOS SA...

Page 13: ...746 E R 41 732099 Rev D...

Page 14: ......

Page 15: ...icherheitsvorrichtungen Norm EN 12978 erm glichen den Schutz eventueller Ge fahrenbereiche vor mechanischen Bewegungsrisiken wie zum Beispiel Quetschungen Mitschleifen oder Schnittverletzungen 17 F r...

Page 16: ...Sede legale FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www geniusg com SPRINT 382 SPRINT 383 12 00058I0112 Rev 6...

Reviews: