14.6
TIMED CLOSURE TIME
Sets the reversal to timed closure following activation of the
Gatecoder anti-crushing safety or the “SAFE-OP” safety.
REG. No.
VALUE
FUNCTION
DEFAULT
50
seconds
timed closure time
2
Default: 2 seconds
14.7
OPENING OVER-PUSHING STROKE
Sets the final opening time at full speed.
When the motors complete their opening cycle, they are activated
again for opening at full speed for the set time.
REG. No.
VALUE
FUNCTION
DEFAULT
51
seconds
opening over-pushing stroke
0
Default: opening over-pushing stroke disabled (0 sec.)
14.8
CLOSURE OVER-PUSHING STROKE
Sets the final closing time at full speed.
When the motors complete their closure cycle, they are activated
again for closure at full speed for the set time.
REG. No.
VALUE
FUNCTION
DEFAULT
52
seconds
closure over-pushing stroke
0
Default: closure over-pushing stroke disabled (0 sec.)
14.9
OBSTACLE RECOGNITION TIME
The anti-crushing safety is obtained using the Gatecoder, by
way of electronic speed control performed by the 460P.
An obstacle is detected when it impedes the normal movement
of the automation.
The interval of time between the obstacle impeding movement
and the activation of timed reversal of movement or
stopping can be programmed:
REG. No.
VALUE
FUNCTION
DEFAULT
53
seconds
obstacle recognition (full speed)
1
Default: 1 second
1) Obstacle recognition time at full speed
This is the time set to activate the anti-crushing safety (timed
reversal) in the presence of an obstacle during movement at full
speed (not during deceleration).
2) End stop recognition time during deceleration
This is the time set to stop the motors in the presence of an
obstacle during deceleration. It is also the time used for recogni-
tion of the mechanical end stop during decleration.
Default: 4 seconds
14.11 ELECTRIC LOCK ACTIVATION TIME
Sets the duration of electric lock activation.
➲
The set value must be lower than the opening and closing leaf
delay times.
REG. No.
VALUE
FUNCTION
DEFAULT
56
seconds
electric lock activation time
Default: 1 second
REG. No.
VALUE
FUNCTION
DEFAULT
54
seconds
obstacle recognition (deceleration)
4
14.12 TIMER FUNCTION
The 460P electronic control unit can be programmed for
access control via an external timer.
Use automatic logics (A or S) only.
Operating notes:
1) Closure of timer contact
The leaf or leaves open and remain open until the timer
contact reopens.
2) Opening of timer contact
The leaf or leaves close and are set up for normal operation.
3) If the power supply fails during the opening time period
controlled by the timer, when power returns the 460P powers
the motors to open, thereby returning the leaf or leaves to
the open condition.
4) If the timer acts on the single leaf, giving the total opening
command (OPEN-A) while the single leaf is open also causes
the other leaf to open.
Make the connection as shown in Fig.9, choosing whether
the timer is to act on total opening (OPEN-A) or partial
opening (OPEN-B) of the leaves and set the following registers.
1
REG. No.
VALUE
FUNCTION
DEFAULT
5 *
XX1XXXXX timer function
Default: timer function disabled
6 *
XXXXX1X1 timer function
14.10 REVERSING STROKE DURATION
Sets the duration of the opening/closing reversing stroke. The
reversing stroke, which facilitates operation of the electric
locks, is performed if set in the FAACTOTUM programming.
REG. No.
VALUE
FUNCTION
DEFAULT
55
seconds
duration of reversing stroke
1
Default: 1 second
18
14.5
TIMED OPENING TIME
This sets the timed opening reversal time following activation of
the Gatecoder anti-crushing safety or the “SAFE-CL” safety.
REG. No.
VALUE
FUNCTION
DEFAULT
49
seconds
timed opening time
2
Default: 2 seconds
TIMER
IN1 IN2
6
OPEN-A
OPEN-B
-
460P
Fig. 9
XX0XXXXX
XXXXX0X0