IMPULSE COMMAND

MOTOR 1

ò

 OPEN

ñ

 CLOSE

CLEAR STOP

ENT CONT.

Motor M1 operation test:

ò

= Start motor M1 for opening
= Start motor M1 for closure

CLEAR = Stop movement
ENTER = Stop movement and go to subsequent menu

ò

ENTER

PG

PG

CLEAR

ESC

1

F1

2

F2

ENTER

ENTER

IMPULSE COMMAND

MOTOR 2

ò

 OPEN

ñ

 CLOSE

CLEAR STOP

ENT CONT.

13

2) LAMP      =  State of warning lamp
The possible states are:
- ON

= Warning light on

- OFF

= Warning light off

3) OUT F.TX  =  State of photocell projector power supply
The possible states are:
- ON

= Supply to projectors on

- OFF

= Supply to projectors off

If the Failsafe is not enabled, the normal state is ON. Only when the photocell
check is performed (Failsafe enabled) does the state momentarily become OFF.

4) RX  =  Result of FAILSAFE check
The possible states are:
- OK = The Failsafe has run correctly
- KO = The Failsafe has found a fault

With the FAACTOTUM connected to the card, it is possible to check the state of
the automation according to the operation of the various activation devices
under this menu.

Press ENTER to continue.

➲ 

This menu appears only if “NUMBER OF OPERATORS = 2” has been set.

Motor M2 operation test:

ò

= Start motor M2 for opening
= Start motor M2 for closure

CLEAR = Stop the movement
ENTER = Stop movement and go to next menu

ò

ENTER

PG

PG

CLEAR

ESC

CYCLES COUNTER

TOTAL

XXXXXXXX

CYCLES COUNTER

PARTIAL

XXXXXXXX

CLEAR   RESET

ENTER

ENTER

IMPULSE COMMAND
1 OPEN-A

2 OPEN-B

3 STOP

4 CLOSE

ESC TO EXIT

From the time of its installation, the 460P counts the number of cycles performed
by the automation to give an idea of its degree of usage.
A cycle is counted upon each opening movement.
The total number of cycles (which cannot be reset) is shown in this menu.
Press ENTER to continue.

Display of number of cycles performed since last reset.
Press the CLEAR key to reset the counter.
Press ENTER to continue.

➲ 

The number of partial cycles is contained inside the configuration program

and is overwritten every time a program (saved in the FAACTOTUM internal
memory) is transferred to the card.

The control pulses are sent using the following number keys:
1=OPEN-A

2=OPEN-B

3=STOP

4=CLOSE

 Whereas the control pulses sent by external activation devices reach the

microprocessor via special electronic components called optoisolators, those
sent via the FAACTOTUM reach the microprocessor directly.
This means that it is possible not only to test the automation without the need
to operate on the external activation devices, but also to test the efficiency of
the optoisolators.
Press ENTER to continue.

TEST MOTOR?

1->YES

   2  NO

ENTER

SELECT MODE

(cont.)

(cont.)

ENTER

ENTER

ENTER

ESC

CLEAR

1

F1

2

F2

3

F3

4

F4

Select option:
1 = Perform motor operation test
2 = Do not perform motor operation test

1

F1

2

F2

or

ENTER

+

Make the selection by moving the arrow-shaped cursor alongside the desired
option using the 

ï

 and 

ð

 keys and pressing ENTER, or key in the corresponding

number directly.

Summary of Contents for FAACTOTUM

Page 1: ...FAACTOTUM FAACTOTUM R...

Page 2: ......

Page 3: ...ms or it can be modified Besides programming the FAACTOTUM can be used to perform diagnostics and to check the operation of the automation and the connection to an external PC appropriate software pro...

Page 4: ...rol unit 460P The FAACTOTUMcanbeconnectedtothepowerpackwiththe batteries fitted since the external power source is used preferentiallytosavebatterycharge The internal batteries operate as a buffer sup...

Page 5: ...LP When enabled this key provides useful information regarding programming 8 SHIFT SHIFT Press this key to activate the alternative function of keys which have a double function e g alphanumeric keys...

Page 6: ...his function prevents the FAACTOTUM from being used by anyone who does not know the password but it does not prevent access to the configuration saved on the 460P card Select the mode by moving the ar...

Page 7: ...cter alphanumeric identification If you know the number enter it the corresponding identification will appear and press ENTER Alternatively pressing the and keys displays all the memory locations one...

Page 8: ...uses a short closure movement before the leaves open to facilitateoperationoftheclosedpositionelectriclocks Selectoption 1 Inversion stroke enabled 2 Inversion stroke disabled 1 F1 2 F2 or ENTER Make...

Page 9: ...through the logics avail able and their identifications When the desired logic appears press ENTER to select it If you know the location key in the number the identification appears and press ENTER o...

Page 10: ...rrow on the display moves to select the effect of the subsequent pulse Close Leaf 2 completely and press ENTER cont ASSOCIATE CHOSEN FUNCTION WITH INPUT AND PRESS ENTER INP 2 XXXXXX ENTER INPUT MODULE...

Page 11: ...eviously been set When the key is pressed Leaf 2 begins to close and the arrow on the display moves alongside the DECELERATION option When Leaf 2 has reached the position where you wish closing decele...

Page 12: ...s for entering the register value DEC to enter the register value in decimal BIN to enter the register value in binary If DEC is selected enter the value using the number keys If BIN is selected press...

Page 13: ...After entering the identification press ENTER to save and proceed If you select an occupied location saving will cause the resident configuration to be overwritten A K U C M W E O Y G Q I S B D F H J...

Page 14: ...omplete diagnostics on the automation the FAACTOTUM must be connected to the 460P electronic control unit Press ENTER to continue ENTER The menus contained in the diagnostics with the exception of the...

Page 15: ...IMPULSE COMMAND 1 OPEN A 2 OPEN B 3 STOP 4 CLOSE ESC TO EXIT From the time of its installation the 460P counts the number of cycles performed by the automation to give an idea of its degree of usage...

Page 16: ...nfiguration on the card it can be loaded from this menu Select option 1 Load 460P standard configuration resident in the FAACTOTUM 2 Ignore the question and proceed 1 F1 2 F2 SELECT MODE 14 1 F1 2 F2...

Page 17: ...time as the Gatecoder and vice versa 5 With the sole exception given below it is not possible to assign the same function to more than one terminal 6 The 460P card terminal IN2 can also be configured...

Page 18: ...XXXXXX 60Hzmainspowersupply 30 XXXXXXX0 FAILSAFEoninputFSW CLdisabled disabled XXXXXXX1 FAILSAFEoninputFSW CLenabled XXXXXX0X FAILSAFEoninputFSW OPdisabled disabled XXXXXX1X FAILSAFEoninputFSW OPenabl...

Page 19: ...mand The contact remains closed until the state is reset REG No VALUE FUNCTION DEFAULT 14 1001XXXX panicstateactivated 0000XXXX Default standardwarninglightfunction 3 Automation open state contact The...

Page 20: ...ds 14 11 ELECTRIC LOCK ACTIVATION TIME Sets the duration of electric lock activation Thesetvaluemustbelowerthantheopeningandclosingleaf delay times REG No VALUE FUNCTION DEFAULT 56 seconds electric lo...

Page 21: ......

Page 22: ......

Reviews: