14.1 PRE-FLASHING

Pre-flashing is a function which, with the automation stopped
and the flashing light off, allows the flashing light to come on a
few seconds before movement begins. Programmable types of
pre-flashing:

1) Opening pre-flashing 1

The flashing light is powered for the set time before switching
from the closed/locked state to the opening state.

2) Closure pre-flashing 1

The flashing light is powered for the set time before switching
from the open/open on pause/stopped state to the closure state.

3) Pre-flashing at end of pause

The flashing light is powered for the set time at the end of the
pause before starting the movement.

14.2 FLASHING LIGHT ON DURING PAUSE

The flashing light is powered for the entire duration of the pause.

REG.  No.

VALUE

FUNCTION

DEFAULT

45

seconds

opening pre-flashing time

0

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * XXXXXX1X pre-flashing at end of pause

XXXXXX0X

REG.  No.

VALUE

FUNCTION

DEFAULT

14  * XXXXX1XX flashing light on during pause

XXXXX0XX

14.3 WARNING LIGHT ON DURING CLOSURE

Sets the warning light to stay on even during closure: the only
state in which it is off is automation closed.

Default: opening pre-flashing disabled (0 seconds)

Default: closing pre-flashing disabled (0 seconds)

Default: pre-flashing at end of pause disabled

Default: flashing light off during pause

14.4 WARNING LIGHT OUTPUT OPERATION

Allows the 460P warning light output (N.O. contact) to be used for
other functions:

1) Timed courtesy light contact

The warning light output N.O. contact closes for a settable time
(Reg.79) during each opening, closure, photocell operation and
pause start of the automation.
Every state which causes the contact to close resets and restarts
the timing count.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 0100XXXX warning light on during closure

0000XXXX

Default: standard operation of the warning lamp is:
automation closed =

warning light off

automation closing =

warning light flashing

all other states

=

warning light on

2) Panic state active contact

The warning light output N.O. contact closes when the panic
state is activated in the electronic control unit 460P following the
“EMERG” command.
The contact remains closed until the state is reset.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1001XXXX panic state activated

0000XXXX

Default: standard warning light function

3) Automation open state contact

The warning light output N.O. contact closes for the entire time
the automation remains in the open or the open on pause states.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1010XXXX automation open/pause state

0000XXXX

Default: standard warning light function

4) Automation opening state contact

The warning light output N.O. contact closes for the entire time
the automation remains in the opening state.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1011XXXX automation opening state

0000XXXX

Default: standard warning light function

5) Automation closure state contact

The warning light output N.O. contact closes for the entire time
the automation remains in the closure state.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1100XXXX automation closure state

0000XXXX

Default: standard warning light function

6) Stop impulse active contact

The warning light output N.O. contact closes for the entire time
the stop button is pressed.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1101XXXX stop button pressed

0000XXXX

Default: standard warning light function

7) Automation pause state contact

The warning light output N.O. contact closes for the entire time
the automation remains in the pause state.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1110XXXX automation in pause state

0000XXXX

Default: standard warning light function

8) Automation closed state contact

The warning light output N.O. contact closes for the entire time
the automation remains in the closed state.

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1111XXXX automation closed state

0000XXXX

Default: standard warning light function

REG.  No.

VALUE

FUNCTION

DEFAULT

46

seconds

closure pre-flashing time

0

14.

EXAMPLES OF REGISTER SETTINGS

The following are some examples of register settings for the most
useful functions, complete with explanations.

 The registers marked with an asterisk (*) are “Logic registers”

(see chapter 13).

REG.  No.

VALUE

FUNCTION

DEFAULT

79

seconds

contact closure time

      

 100

Default: 100 seconds

17

REG.  No.

VALUE

FUNCTION

DEFAULT

14 * 1000XXXX timed courtesy contact

0000XXXX

Default: standard warning light function

REG.  No.

VALUE

FUNCTION

DEFAULT

48

seconds

pre-flashing time at end of pause

0

Default: 0 seconds

Summary of Contents for FAACTOTUM

Page 1: ...FAACTOTUM FAACTOTUM R...

Page 2: ......

Page 3: ...ms or it can be modified Besides programming the FAACTOTUM can be used to perform diagnostics and to check the operation of the automation and the connection to an external PC appropriate software pro...

Page 4: ...rol unit 460P The FAACTOTUMcanbeconnectedtothepowerpackwiththe batteries fitted since the external power source is used preferentiallytosavebatterycharge The internal batteries operate as a buffer sup...

Page 5: ...LP When enabled this key provides useful information regarding programming 8 SHIFT SHIFT Press this key to activate the alternative function of keys which have a double function e g alphanumeric keys...

Page 6: ...his function prevents the FAACTOTUM from being used by anyone who does not know the password but it does not prevent access to the configuration saved on the 460P card Select the mode by moving the ar...

Page 7: ...cter alphanumeric identification If you know the number enter it the corresponding identification will appear and press ENTER Alternatively pressing the and keys displays all the memory locations one...

Page 8: ...uses a short closure movement before the leaves open to facilitateoperationoftheclosedpositionelectriclocks Selectoption 1 Inversion stroke enabled 2 Inversion stroke disabled 1 F1 2 F2 or ENTER Make...

Page 9: ...through the logics avail able and their identifications When the desired logic appears press ENTER to select it If you know the location key in the number the identification appears and press ENTER o...

Page 10: ...rrow on the display moves to select the effect of the subsequent pulse Close Leaf 2 completely and press ENTER cont ASSOCIATE CHOSEN FUNCTION WITH INPUT AND PRESS ENTER INP 2 XXXXXX ENTER INPUT MODULE...

Page 11: ...eviously been set When the key is pressed Leaf 2 begins to close and the arrow on the display moves alongside the DECELERATION option When Leaf 2 has reached the position where you wish closing decele...

Page 12: ...s for entering the register value DEC to enter the register value in decimal BIN to enter the register value in binary If DEC is selected enter the value using the number keys If BIN is selected press...

Page 13: ...After entering the identification press ENTER to save and proceed If you select an occupied location saving will cause the resident configuration to be overwritten A K U C M W E O Y G Q I S B D F H J...

Page 14: ...omplete diagnostics on the automation the FAACTOTUM must be connected to the 460P electronic control unit Press ENTER to continue ENTER The menus contained in the diagnostics with the exception of the...

Page 15: ...IMPULSE COMMAND 1 OPEN A 2 OPEN B 3 STOP 4 CLOSE ESC TO EXIT From the time of its installation the 460P counts the number of cycles performed by the automation to give an idea of its degree of usage...

Page 16: ...nfiguration on the card it can be loaded from this menu Select option 1 Load 460P standard configuration resident in the FAACTOTUM 2 Ignore the question and proceed 1 F1 2 F2 SELECT MODE 14 1 F1 2 F2...

Page 17: ...time as the Gatecoder and vice versa 5 With the sole exception given below it is not possible to assign the same function to more than one terminal 6 The 460P card terminal IN2 can also be configured...

Page 18: ...XXXXXX 60Hzmainspowersupply 30 XXXXXXX0 FAILSAFEoninputFSW CLdisabled disabled XXXXXXX1 FAILSAFEoninputFSW CLenabled XXXXXX0X FAILSAFEoninputFSW OPdisabled disabled XXXXXX1X FAILSAFEoninputFSW OPenabl...

Page 19: ...mand The contact remains closed until the state is reset REG No VALUE FUNCTION DEFAULT 14 1001XXXX panicstateactivated 0000XXXX Default standardwarninglightfunction 3 Automation open state contact The...

Page 20: ...ds 14 11 ELECTRIC LOCK ACTIVATION TIME Sets the duration of electric lock activation Thesetvaluemustbelowerthantheopeningandclosingleaf delay times REG No VALUE FUNCTION DEFAULT 56 seconds electric lo...

Page 21: ......

Page 22: ......

Reviews: